INSTALL HANDLES

6

 

Push ADAPTER (1) on VALVE

 

STEM (2), so that the hole of the

5

 

ADAPTER (1) without spline is

facing up.

6

INSTALLATION OF OPTIONAL METAL LEVER

HANDLES (Supplied with Faucet)

Thread PORCELIAN LEVER HANDLE (2) counter-clockwise

and remove INDEX BUTTON with MOUNTING ROD ASSEMBLY (1).

Insert MOUNTING ROD ASSEMBLY (1) into METAL HANDLE (3)

Thread HANDLE BASE (3) onto

VALVE ESCUTCHEON (7)

Push LEVER BALL (4) onto

4

and HANDLE COLLAR (4).

Thread HANDLE ASSEMBLY (6) into ball of HANDLE BASE (5) and tighten.

ADAPTER (1).

TOP

Find correct position of HANDLE (4) by adjusting male teeth on ADAPTER (1) to female teeth in

LEVER BALL (4).

Secure LEVER BALL (4) with HANDLE SCREW (5).

SPLINE END

Push INDEX CAP (6) DOWN in hole of LEVER BALL (4).

3

1

2

7

24

3

1

6

5

10 TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER

SUPPLIES (2) and check all connections for leaks.

Remove AERATOR (3).

1

Operate both HANDLES (1) to flush water lines thoroughly.

Replace AERATOR (3).

11 CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (5) and fill Sink with water. Check that DRAIN STOPPER (4) makes a good seal and retains water in Sink. If STOPPER (4) does not seal properly, please refer to “Troubleshooting Guide” in these instructions.

Release POP-UP KNOB (5) down and check all drain connections and "P" trap for leaks. Tighten if necessary.

5

1

3

4

WASTE

OUTLET

2

COLD

“P” TRAP

2

HOT

12 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE

PRODUCT WITH SOAPS, ACID,

POLISH, ABRASIVES, HARSH

CLEANERS, OR A CLOTH WITH

A COARSE SURFACE.

13 SERVICE

To change direction of handle rotation, proceed as follows:

Turn valve to OFF position.

 

 

Remove INSERT and HANDLE SCREW.

2

90

Slip HANDLE with ADAPTER off.

 

Remove SPRING CLIP (1).

 

1

Lift STOP WASHER (2), turn 90 and replace.

 

Replace SPRING CLIP (1).

 

 

Replace ADAPTER, HANDLE, SCREW, and INSERT.

 

 

Spray may accumulate dirt causing distorted and reduced water flow. Remove spray and rinse clean.

Replace Spray and operate handles several times from OFF to ON position. Do not force, handles turn only 90˚.

US60385 Rev. 1 . 2

4

Image 4
Contents Install Spout 1A Install Valve BodyInstall POP-UP Drain Install Black GasketInstall Gray Locknut POP-UP KnobAttach Cable Connector Check Operation of POP-UPMake Water Supply and Waste Connections HOTInstall Handles Installation of Optional Metal LeverTest Installed Fitting Check Drain Connections