| R |
|
|
|
|
| INSTALLATION INSTRUCTIONS |
|
|
|
|
| FOR TYPE 2 HUNTER CEILING FAN WITH LIGHT |
|
|
|
| READ AND SAVE THESE INSTRUCTIONS |
| |
CAUTION: | 1. READ ENTIRE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. |
| |||
| 2. TO AVOID POSSIBLE ELECTRICAL SHOCK, BE CERTAIN ELECTRICITY IS SHUT OFF AT MAIN PANEL |
| |||
| BEFORE WIRING. |
| |||
| 3. ALL WIRING MUST BE IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES. IF YOU ARE |
| |||
| UNFAMILIAR WITH WIRING, YOU SHOULD USE A QUALIFIED ELECTRICIAN. |
| |||
WARNING: | 1. TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT USE A SOLID STATE SPEED CONTROL |
| |||
| WITH THIS FAN. USE HUNTER CONTROL MODEL 22691. |
| |||
| 2. TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE BLADE BRACKETS WHEN INSTALLING |
| |||
| THE BRACKETS, BALANCING THE BLADES, OR CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS |
| |||
| IN BETWEEN ROTATING FAN BLADES. |
| |||
STEP 1: |
|
| |||
| A. SELECT INSTALLATION SITE. CHECK TO MAKE SURE THAT IN NORMAL USE NO OBJECT CAN COME |
| |||
| IN CONTACT WITH THE ROTATING FAN BLADES. THE MOUNTING SITE SHOULD ALSO MEET THE |
| |||
| PRECAUTIONS LISTED IN STEP 3 BELOW. |
| |||
| B. INSTALLATION HARDWARE IS INCLUDED FOR A STANDARD DRYWALL OR PLASTER CEILING. YOU WILL |
| |||
| NEED A 4" X |
| |||
| FROM ANY HARDWARE STORE OR ELECTRICAL SUPPLY HOUSE. |
| |||
| C. THE FAN BLADES MUST BE MOUNTED AT LEAST 7' ABOVE THE FLOOR. FOR MAXIMUM EFFICIENCY, |
| |||
| THEY SHOULD NOT HAVE ANY OBSTRUCTION (WALLS, POSTS, ETC.) WITHIN 24" OF THE BLADE TIPS. |
| |||
| SEE FIGURE 1. FOR MOUNTING DISTANCES. |
| |||
|
|
| |||
|
|
| 10" |
| |
| 8 FT. MIN |
| |||
| CEILING TO FLOOR |
| |||
|
|
| 24" |
| |
|
|
| |||
|
|
|
| CLEARANCE |
|
|
|
|
| TO OBSTRUCTIONS |
|
|
|
|
|
|
|
|
|
| 84" MIN |
| |
|
|
| TO FLOOR |
| |
|
|
|
| FIGURE 1. |
|
|
|
|
|
| |
|
|
|
|
|
|
STEP 2: | INSPECTION OF FAN AND LIGHT |
| |||
| A. UNPACK UNIT CAREFULLY TO AVOID ANY DAMAGE TO THE COMPONENTS. |
| |||
| B. CHECK FOR ANY SHIPPING DAMAGE TO THE MOTOR, FAN BLADES, SWITCH HOUSING, AND GLOBE. IF |
| |||
| MORE THAN ONE FAN IS BEING INSTALLED, KEEP THE MATCHED AND BALANCED FAN BLADES IN SETS |
| |||
| AS THEY WERE SHIPPED. SHOULD ONE OF THE FAN BLADES BECOME DAMAGED DURING SHIPMENT, |
| |||
| RETURN ALL BLADES IN THE SET FOR REPLACEMENT. |
| |||
| C. CHECK CONTENTS TO BE CERTAIN IT CONTAINS A BAG OF PARTS. |
| |||
STEP 3: | INSTALLATION OF OUTLET BOX AND |
| |||
CAUTION: | YOUR HUNTER CEILING FAN WITH ACCESSORIES CAN WEIGH UP TO 35 LBS. THE FOLLOWING |
| |||
| PRECAUTIONS MUST BE TAKEN FOR SAFETY AND TO ENSURE THAT YOUR FAN IS SECURELY MOUNTED |
| |||
| TO THE CEILING. |
| |||
| BE CERTAIN ELECTRICITY IS "OFF" AT THE FUSE PANEL WHEN INSPECTING OR REPAIRING |
| |||
| INSTALLATION SITE. |
| |||
| ALL WIRING MUST MEET LOCAL AND NATIONAL ELECTRICAL CODES. |
| |||
| DO NOT MOUNT DIRECTLY TO AN UNSUPPORTED CEILING OR TO AN ELECTRICAL OUTLET. MOUNTING |
| |||
| MUST SUPPORT A 35 LB. FAN WITH ACCESSORIES. |
| |||
| A. SECURE A METALLIC OUTLET BOX 4" X |
| |||
| BETWEEN TWO CEILING JOISTS AS SHOWN IN FIGURE 2. THE OUTLET BOX MUST BE RECESSED IN |
| |||
| THE CEILING BY 1/16" MINIMUM. SECURE THE OUTLET BOX TO THE CROSS BRACE BY DRILLING |
| |||
| (2) PILOT HOLES NO LARGER THAN THE MINOR DIAMETER OF THE WOODSCREWS (5/64") AND USE |
| |||
| TWO #8 X |
| |||
| BOX. ORIENT THE BOX SO THE OUTERMOST HOLES ARE ALIGNED WITH THE 2 X 4 BRACE. THE |
| |||
| OUTERMOST HOLES WILL BE USED IN STEP 4B. |
| |||
CAUTION: | DO NOT USE A LUBRICANT ON SCREWS. |
| |||
| B. BRING ELECTRICAL CABLE INTO THE OUTLET BOX AND ATTACH WITH AN APPROVED CONNECTOR. |
| |||
| MAKE CERTAIN THAT WIRING MEETS ALL NATIONAL AND LOCAL ELECTRICAL CODES. WIRE LEADS |
| |||
| SHOULD EXTEND AT LEAST 6" BEYOND OUTLET BOX FOR EASE IN MAKING CONNECTIONS. SEE |
| |||
| FIGURE 3. |
| |||
|
|
|