STEP 10: OPERATION OF FAN

STEP 10: OPERATION OF FAN

A. TURN ELECTRICAL SERVICE ON AT MAIN PANEL.

B. SWITCH OPERATES IN THIS SEQUENCE: "HIGH," "MEDIUM," "LOW," "OFF." PULL CHAIN SLOWLY TO OPERATE.

ALSO, RELEASE THE CHAIN SLOWLY SO AS TO PREVENT CHAIN FROM FLYING UP INTO BLADES,

POSSIBLY RESULTING IN DAMAGE TO BLADES OR PULL CHAIN. THE BREAKAWAY CONNECTOR IS DESIGNED

TO SEPARATE FROM THE CHAIN AT A PREDETERMINED FORCE. IF THIS SEPARATION OCCURS,

SIMPLY REINSERT THE CONNECTOR. IT CAN BE USED AGAIN AND AGAIN. SEE FIGURE 9.

C. MOTOR IS ELECTRICALLY REVERSIBLE. WHEN FIRST OPERATING FAN, DETERMINE DIRECTION OF AIR

FLOW. IF YOU WISH TO CHANGE DIRECTION, SWITCH FAN OFF AND ALLOW TO STOP. SLIDE REVERSING

SWITCH TO THE OPPOSITE POSITION AND SWITCH FAN BACK ON. SEE FIGURE 9.

EXTENSION PIPES

IF YOUR CEILING IS HIGHER THAN EIGHT FEET, YOU MAY ELECT TO USE A LONGER HANGER PIPE.

EXTENSION PIPES ARE AVAILABLE AT YOUR HUNTER DEALER AND MAY BE ADAPTED TO FIT YOUR FAN.

SPEED CONTROL

AS AN OPTION, A WALL MOUNTED SPEED CONTROL SWITCH IS AVAILABLE FROM YOUR HUNTER DEALER.

TROUBLESHOOTING GUIDE

PROBLEM

PROBABLE CAUSE

SOLUTION

 

 

 

1. NOTHING HAPPENS

1. POWER TURNED OFF OR FUSE BLOWN.

1. TURN POWER ON OR REPLACE FUSE.

FAN DOES NOT MOVE. *

2. LOOSE WIRE CONNECTIONS OR

2. LOOSEN CANOPY, CHECK ALL CONNECTIONS (TURN

 

WRONG CONNECTIONS.

POWER OFF WHILE CHECKING).

 

3. MOTOR REVERSING SWITCH NOT ENGAGED.

3. PUSH SWITCH FIRMLY TO ONE SIDE OR THE OTHER.

 

4. PULL CHAIN SWITCH NOT "ON".

4. PULL SWITCH CHAIN.

*NOTE: IF BLADES WILL NOT TURN BY HAND, CONTACT YOUR NEAREST SERVICE REPRESENTATIVE.

 

 

 

 

2. NOISY OPERATION.

1. BLADE BRACKETS LOOSELY SCREWED TO MOTOR.

1. TIGHTEN SCREWS UNTIL SNUG.

 

2. BLADE SCREWED LOOSELY TO BLADE BRACKET.

2. TIGHTEN SCREWS.

 

3. BLADE CRACKED.

3. REPLACE ENTIRE SET OF BLADES.

 

4. NON-APPROVED SPEED CONTROL BEING USED.

4. CHANGE TO APPROVED SPEED CONTROL.

 

5, GLOBE IS VIBRATING AND EMITTING NOISE.

5. RE-ADJUST 3 GLOBE MOUNTING SCREWS.

 

 

 

3. EXCESSIVE WOBBLING.

1. UNBALANCED BLADES.

1. USE BALANCING KIT (SEE STEP 8C).

 

2. FAN TOO CLOSE TO VAULTED CEILING.

2. LOWER OR MOVE FAN.

 

3. LOOSE BLADES OR BLADE BRACKETS.

3. TIGHTEN ALL SCREWS.

 

4. FAN NOT SECURE ON HANGER ASSEMBLY.

4. TURN POWER OFF, SUPPORT FAN VERY CAREFULLY,

 

 

LOOSEN CANOPY AND HANG CORRECTLY.

WHEN SWITCHING FROM MEDIUM TO LOW SPEED, YOU MAY NOTICE SOME FAN WOBBLE. WHEN FAN SPEED STABILIZES AT LOW

SPEED, WOBBLE WILL DISAPPEAR. IF YOU HAVE CHECKED THE ABOVE PROBLEMS AND STILL HAVE TROUBLE, CALL (901) 745-9222.

 

 

 