PYLE Audio MN300HGA installation manual Installation, Installing Thermostat Sensing Bulb

Page 7

WARNING: Maintain the minimum clearances shown in Figure 4 . If you can, provide greater clearances from floor, ceiling, and joining wall.

Figure 4 -Mounting Clearaances As Viewed From Front Of Heater

IMPORTANT: Vent-free

heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See

Fresh Air for Combustion and

Ventilation, pages 4 and 5.

INSTALLING THERMOSTAT SENSING BULB

For MN300TGA

1.Pull out the sensing bulb from the two clips located in the shippng position according to the direction as shown by the arrow. There is no need to take out the two bulb clips.

2.Take out the bulb clip from the hardware package and insert it into the square hole and then insert the sensing bulb into the bulb clip (see Figure 5).

Figure 5 - Moving Thermostat Sensing Bulb

INSTALLATION

FASTENING HEATER TO WALL Mounting Bracket

The mounting bracket is located on back panel of heater (see figure 6). It has been taped there for shipping. Remove mounting bracket from back panel.

Figure 6 -Mounting Bracket Location

Removing Lower Front Panel Of Heater

1.Remove two screws near bottom corners of lower front panel .

2.Pull bottom of lower front panel forward, then down (see Figure 7).

Figure 7 - Removing Lower Front Panel Of Heater

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall only in one of two ways:

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

WARNING: Maintain minimum clearances shown in Figure 8. If you can, provide greater clearances from floor and joining wall.

2.Mark screw locations on wall. (see Figure 8)

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

Model MN300HGA MN300TGA

Figure 8 - Mounting Bracket Clearances

7

Image 7
Contents MN300HGA MN300TGA NON-THERMOSTAT Thermostat Model OWNER’S Operation and Installation ManualSafety Information Product Features Unusually Tight Construction Fresh AIR for Combustion VentilationProducing Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Outdoors,Check GAS Type InstallationInstallation Needs Ventilation AIRInstalling Thermostat Sensing Bulb InstallationImportant Do not ham Installing Bottom Mounting ScrewsAttaching Mounting Bracket to Wall Attaching to Wall Anchor MethodImportant Install an Connecting to GAS SupplyRead Before Lighting NFOR Your SAFETYnChecking GAS Connections Thermostat Model MN300TGAThermostat Model MN300TGA Operating Your HeaterShutting Off Burner Only pilot stays lit NON-THERMOSTAT Model MN300HGARead Before Lighting GAS to AppliancePilot Flame Pattern Cleaning ODS/PILOT and BurnerCleaning Burner Pilot AIR Inlet Hole Cleaning Heater CabinetObserved Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Remedy Specifications Illustrated Parts Breakdown ODS/Pilot AssemblyMN300TGA KEY Parts List MN300TGAMN300HGA ODS/Pllot AssemblyKEY MN300HGA NO. Part no Parts List MN300HGA