PYLE Audio NON-THERMOSTAT Model MN300HGA, Read Before Lighting, GAS to Appliance

Page 12

OPERATING YOUR HEATER

NON-THERMOSTAT MODEL

MN300HGA

nFOR YOUR SAFETYn

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch, do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it , call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service

tec hn ic ian to inspect th e appliance and to replace any part of the control system and any gas control which has been under water.

nLIGHTINGn

INSTRUCTIONS

1.STOP! Read the safety information on the side of heater.

2.Check that gas supply to heater is on.

3.Push in control knob slightly

and turn clockwise to the OFF position (see Figure 18).

NOTE: Knob cannot be turned from "PILOT " to "OFF" unless knob is pushed in slightly. Do not force.

4.Wait five minutes to clear out any gas. Then smell for gas,

including near the floor. If you smell gas, STOP! Follow "B" in the safety information on the side of heater. If you don’t smell gas,

g o t o t h e n e xt

s t e p .

5.Push in and turn control knob

counterclockwise to PILOT position. Press in control knob for five(5) seconds.

Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in control knob for 30 seconds. This will allow air to bleed from the gas system.

Figure 18 - Control Knob in The OFF Position

Figure 19 - Pilot

6.With control knob pressed in, push down and release the ignitor button. This will light pilot. If needed, keep pressing ignitor button until pilot lights.

7.Keep control knob depressed for ten (10) seconds after lighting pilot. if pilot goes out, repeat steps 5,6 and 7.

8.To select the desired heating level, partially press down the control knob slightly and rotate

counterclockwise . Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position. Do not operate between locked positions.

nTOTURN OFFn

GAS TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit )

Slightly press in control turn

control

knob clockwise

to the

PILOT

position.

 

nMANUAL LIGHTINGn

PROCEDURE

1.Remove lower front panel (see Figure 7 page 7).

2.Follow steps 1 through 5 under Lighting Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions.

5.Replace lower front panel.

1 2

Image 12
Contents OWNER’S Operation and Installation Manual MN300HGA MN300TGA NON-THERMOSTAT Thermostat ModelSafety Information Product Features Fresh AIR for Combustion Ventilation Producing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Outdoors, Ventilation AIRInstallation Installation NeedsVentilation AIR Check GAS TypeInstallation Installing Thermostat Sensing BulbInstalling Bottom Mounting Screws Attaching Mounting Bracket to WallAttaching to Wall Anchor Method Important Do not hamConnecting to GAS Supply Important Install anNFOR Your SAFETYn Checking GAS ConnectionsThermostat Model MN300TGA Read Before LightingOperating Your Heater Thermostat Model MN300TGANON-THERMOSTAT Model MN300HGA Read Before LightingGAS to Appliance Shutting Off Burner Only pilot stays litCleaning ODS/PILOT and Burner Cleaning Burner Pilot AIR Inlet HoleCleaning Heater Cabinet Pilot Flame PatternTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Remedy Specifications ODS/Pilot Assembly Illustrated Parts BreakdownMN300TGA Parts List MN300TGA KEYODS/Pllot Assembly MN300HGAParts List MN300HGA KEY MN300HGA NO. Part no