Rinnai RCE-229A installation instructions To Cancel the on Timer

Page 16

T I M E R O P E R A T I O N

WARNING

y

y

Ensure there are no obstacles or foreign materials directly in front of the appliance where the warm air will discharge into the room.

Ensure the appliance is not positioned where warm air discharge will blow directly on someone sleeping.

1

Press the “ON Timer” button

The “ON Timer” and “ON/Combustion” (green) indicators will light up.

A preset time will be displayed on the digital monitor.(The first time the ON Timer is preset, this time will be “8.0”) The ON Timer can be selected while the unit is in operation, or while it is off (if set during operation,

pressing the ON Timer button will stop the unit heating and the ON/Combustion indicator will change from red to green). The appliance will remain in standby mode.

2

Presetting the time

Pressing the “T” or “S” buttons alters the preset time. After 10 seconds the digital monitor will go out.

If the display has gone out:

Pressing the “T” or “S” buttons once will show the remaining time on the digital monitor.

Pressing the button more than once will alter the preset time.

3

The heater will operate after reaching the end of the preset time.

“ON/Combustion” Indicator glows red.

The heater will operate at the preset temperature selected in the system memory. The heater will automatically operate at 80°F if the preset temperature is set to “H”.

4

The heater stops automatically after 1 hour.

The”ON Timer” indicator will flash to indicate that heating is about to stop (at approximately 55 minutes). After another 5 minutes the heater will automatically stop heating and turn off completely.

The “ON Timer” indicator will continue to flash until the heater is manually operated again. The “ON/ Combustion” indicator will go out.

Pressing the ON-OFF button will turn off the ON Timer indicator.

TO CANCEL THE ON TIMER

Press the “ON Timer” button or press the “ON-OFF” button.

The setting will be cancelled and the timer indicators will go out.

The ON Timer will be cancelled if the power plug is removed from the power point, a power failure while the appliance was in standby mode, or if the ON Timer setting is cancelled. “00” will flash on the digital monitor when power is reinstated. Pressing the ON button and starting the unit will delete the “00”.

www.rinnaina.com

1 6

Model RCE-229A

Image 16
Contents RCE-229A Silent Servant Convector VENT-FREE Space HeaterB L E N T E N T S General InformationSpecification S F E T Y D E V I C E SUnpack Heater P O R T a N T P O I N T SIncluded in Carton F E T YP O I N T S F E T YP O I N T S A G E a N D Installation M U S T S Installation I N S T R U C T I O N S Location and Clearances GAS ConnectionManual Valve Closed Open Operating Instructions Installation Additional Customer Operating Information„ Room Temperature Adjustment „ Turning on„ Turning OFF „ AUTO-OFF Function„ Economy Mode „ Function Lock„ OFF Timer Operation „ on Timer OperationBefore Selecting the on Timer Confirm M E R O P E R a T I O NTo Cancel the on Timer Maintenance Suggestions Trouble ShootingTroubleshooting C H a R T Wiring Diagram H E M a T I C D R a W I N G S Gas Valve/Burner Assembly Exploded View Fan Blower Assembly Exploded View Electrical Wiring Exploded View R T S L I S T Combustion Chamber Assy Part Name QTY. Remarks Error M E S S a G E S Code Displayed Fault RemedyExtended Warranties are AVAILABLE,CONTACT Rinnai for Details America Corporation

RCE-229A specifications

The Rinnai RCE-229A is a remarkable water heater that embodies advanced technology and efficient performance, meeting the needs of modern households. Designed with the consumer in mind, this appliance showcases exceptional features that not only enhance its functionality but also optimize energy usage.

One of the main features of the RCE-229A is its compact design, making it suitable for installations in tight spaces commonly found in urban environments. The unit's sleek appearance allows it to blend seamlessly into various settings, while its build quality ensures durability and longevity. The RCE-229A is designed for both indoor and outdoor installations, providing flexibility for homeowners.

This water heater operates using advanced gas technology, ensuring rapid heating and consistent temperature control. Equipped with a highly efficient burner system, it delivers hot water on demand without the need for a storage tank. This tankless design significantly reduces energy consumption, as water is heated only when needed, thereby minimizing waste and lowering utility bills.

The RCE-229A features a user-friendly digital control panel that offers precise temperature settings and easy operation. Consumers can easily adjust the temperature to their desired level, giving them full control over their hot water needs. The digital display also provides real-time feedback, allowing users to monitor performance effortlessly.

Safety is a top priority for Rinnai, and the RCE-229A comes equipped with multiple safety features. It includes an automatic shutoff mechanism that activates in case of a malfunction, preventing overheating and potential hazards. The unit also has a built-in flame failure device that ensures the gas supply is cut off if the flame goes out unexpectedly.

Moreover, the RCE-229A boasts a high energy efficiency rating, achieving significant savings in energy costs compared to traditional water heaters. This efficient operation not only benefits homeowners financially but also aligns with environmental sustainability efforts by reducing carbon emissions.

In summary, the Rinnai RCE-229A is a sophisticated water heating solution that combines innovative technology with user-friendly features. Its compact design, energy efficiency, safety mechanisms, and digital controls set it apart in the competitive market of water heaters. This model stands as a testament to Rinnai's commitment to quality and customer satisfaction, making it an excellent choice for anyone seeking a reliable and efficient hot water solution for their home.