Rinnai RCE-229A installation instructions Manual Valve Closed Open

Page 10

I N S T A L L A T I O N I N S T R U C T I O N S

4.Any compound used on the threaded joint of gas piping shall be a type which resists the action of liquefied petroleum gas.

5.Supplied gas pressure must be within the limits shown in the specifications.

6.After completion of gas pipe connections, all joints including the heater must be checked for gas-tightness by means of leak detector solution, soap and water, or an equivalent nonflammable solution, as applicable.

CAUTION: Since some leak test solutions, including soap and water, may cause corrosion or stress cracking, the piping shall be rinsed with water after testing, unless it has been determined that the leak test solution is noncorrosive.

7The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa).

The appliance must be isolated from the gas supply piping system by closing its equipment shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5kPa).

8.A valve supplied must be installed on back of unit at time of installation. This is for compliance to ANSI standard Z21.11.2. Valve is packaged with unit.

MANUAL VALVE

CLOSED

OPEN

9.After completing pipework, secure the heater to the floor. Use the two screws provided, as shown in the drawing. To prevent deforming base plate, do not over torque screws.

www.rinnaina.com

1 0

Model RCE-229A

Image 10
Contents RCE-229A Silent Servant Convector VENT-FREE Space HeaterB L E N T E N T S General InformationSpecification S F E T Y D E V I C E SUnpack Heater P O R T a N T P O I N T SIncluded in Carton F E T YP O I N T S F E T YP O I N T S A G E a N D Installation M U S T S Installation I N S T R U C T I O N S Location and Clearances GAS ConnectionManual Valve Closed Open Operating Instructions Installation Additional Customer Operating Information„ Turning OFF „ Room Temperature Adjustment„ Turning on „ AUTO-OFF Function„ Economy Mode „ Function LockBefore Selecting the on Timer Confirm „ OFF Timer Operation„ on Timer Operation M E R O P E R a T I O NTo Cancel the on Timer Maintenance Suggestions Trouble ShootingTroubleshooting C H a R T Wiring Diagram H E M a T I C D R a W I N G S Gas Valve/Burner Assembly Exploded View Fan Blower Assembly Exploded View Electrical Wiring Exploded View R T S L I S T Combustion Chamber Assy Part Name QTY. Remarks Error M E S S a G E S Code Displayed Fault RemedyExtended Warranties are AVAILABLE,CONTACT Rinnai for Details America Corporation

RCE-229A specifications

The Rinnai RCE-229A is a remarkable water heater that embodies advanced technology and efficient performance, meeting the needs of modern households. Designed with the consumer in mind, this appliance showcases exceptional features that not only enhance its functionality but also optimize energy usage.

One of the main features of the RCE-229A is its compact design, making it suitable for installations in tight spaces commonly found in urban environments. The unit's sleek appearance allows it to blend seamlessly into various settings, while its build quality ensures durability and longevity. The RCE-229A is designed for both indoor and outdoor installations, providing flexibility for homeowners.

This water heater operates using advanced gas technology, ensuring rapid heating and consistent temperature control. Equipped with a highly efficient burner system, it delivers hot water on demand without the need for a storage tank. This tankless design significantly reduces energy consumption, as water is heated only when needed, thereby minimizing waste and lowering utility bills.

The RCE-229A features a user-friendly digital control panel that offers precise temperature settings and easy operation. Consumers can easily adjust the temperature to their desired level, giving them full control over their hot water needs. The digital display also provides real-time feedback, allowing users to monitor performance effortlessly.

Safety is a top priority for Rinnai, and the RCE-229A comes equipped with multiple safety features. It includes an automatic shutoff mechanism that activates in case of a malfunction, preventing overheating and potential hazards. The unit also has a built-in flame failure device that ensures the gas supply is cut off if the flame goes out unexpectedly.

Moreover, the RCE-229A boasts a high energy efficiency rating, achieving significant savings in energy costs compared to traditional water heaters. This efficient operation not only benefits homeowners financially but also aligns with environmental sustainability efforts by reducing carbon emissions.

In summary, the Rinnai RCE-229A is a sophisticated water heating solution that combines innovative technology with user-friendly features. Its compact design, energy efficiency, safety mechanisms, and digital controls set it apart in the competitive market of water heaters. This model stands as a testament to Rinnai's commitment to quality and customer satisfaction, making it an excellent choice for anyone seeking a reliable and efficient hot water solution for their home.