FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your finger to push with. Never use tools. If the button will not reactivate by touch, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

STOP! Read the safety information above on this label. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

1.Turn off all electric power to the appliance via

the ON/OFF button on the control panel. Locate manual gas valve to be found on back side of heater.

2.Turn Manual valve clockwiseto the full OFF position.

3.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety information above on

MANUAL VALVE

CLOSEDOPEN

this label. If you don’t smell gas, go to next step.

4.Turn Manual gas valve to the full ON position.

5.Turn on all electric power to the appliance.

6.Press ON/OFF button to “ON”.

7.Set the thermostat to desired setting.

8.Burner is lit when operation lamp glows red.

9.If operation lamp is flashing red, burner has not been lit.

10.If the appliance will not operate, follow the instructions “To turn off gas to appliance” and call your service technician or gas supplier.

Room Temperature

Display

Filter Warning Lamp

Temperature Temperature Function Ignition

Down UpLock Button

TO TURN OFF GAS TO APPLIANCE

1.Turn off electric power to the appliance using the ON/ OFF switch located on the control panel.

2.Turn manual valve clockwise to the full OFF position.

NOTE: The fan will continue to operate until the appliance is cool, do not turn the appliance off by unplugging it from the wall. Keep burner and control compartment clean. See installation and operating instructions accompanying heater.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause personal injury or loss of life. Refer to the owner’s information manual provided with this appliance. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Model RCE-229A

1 1

800-621-9419

Image 11
Contents Silent Servant Convector VENT-FREE Space Heater RCE-229AGeneral Information B L E N T E N T SF E T Y D E V I C E S Specification SIncluded in Carton P O R T a N T P O I N T SUnpack Heater F E T YP O I N T S F E T YP O I N T S A G E a N D Installation M U S T S Installation I N S T R U C T I O N S GAS Connection Location and ClearancesManual Valve Closed Open Operating Instructions Additional Customer Operating Information Installation„ AUTO-OFF Function „ Room Temperature Adjustment„ Turning on „ Turning OFF„ Function Lock „ Economy ModeM E R O P E R a T I O N „ OFF Timer Operation„ on Timer Operation Before Selecting the on Timer ConfirmTo Cancel the on Timer Trouble Shooting Maintenance SuggestionsTroubleshooting C H a R T Wiring Diagram H E M a T I C D R a W I N G S Gas Valve/Burner Assembly Exploded View Fan Blower Assembly Exploded View Electrical Wiring Exploded View R T S L I S T Combustion Chamber Assy Part Name QTY. Remarks Code Displayed Fault Remedy Error M E S S a G E SAmerica Corporation Extended Warranties are AVAILABLE,CONTACT Rinnai for Details

RCE-229A specifications

The Rinnai RCE-229A is a remarkable water heater that embodies advanced technology and efficient performance, meeting the needs of modern households. Designed with the consumer in mind, this appliance showcases exceptional features that not only enhance its functionality but also optimize energy usage.

One of the main features of the RCE-229A is its compact design, making it suitable for installations in tight spaces commonly found in urban environments. The unit's sleek appearance allows it to blend seamlessly into various settings, while its build quality ensures durability and longevity. The RCE-229A is designed for both indoor and outdoor installations, providing flexibility for homeowners.

This water heater operates using advanced gas technology, ensuring rapid heating and consistent temperature control. Equipped with a highly efficient burner system, it delivers hot water on demand without the need for a storage tank. This tankless design significantly reduces energy consumption, as water is heated only when needed, thereby minimizing waste and lowering utility bills.

The RCE-229A features a user-friendly digital control panel that offers precise temperature settings and easy operation. Consumers can easily adjust the temperature to their desired level, giving them full control over their hot water needs. The digital display also provides real-time feedback, allowing users to monitor performance effortlessly.

Safety is a top priority for Rinnai, and the RCE-229A comes equipped with multiple safety features. It includes an automatic shutoff mechanism that activates in case of a malfunction, preventing overheating and potential hazards. The unit also has a built-in flame failure device that ensures the gas supply is cut off if the flame goes out unexpectedly.

Moreover, the RCE-229A boasts a high energy efficiency rating, achieving significant savings in energy costs compared to traditional water heaters. This efficient operation not only benefits homeowners financially but also aligns with environmental sustainability efforts by reducing carbon emissions.

In summary, the Rinnai RCE-229A is a sophisticated water heating solution that combines innovative technology with user-friendly features. Its compact design, energy efficiency, safety mechanisms, and digital controls set it apart in the competitive market of water heaters. This model stands as a testament to Rinnai's commitment to quality and customer satisfaction, making it an excellent choice for anyone seeking a reliable and efficient hot water solution for their home.