Rinnai REU - 16 FUA - E Installation Instructions Connections, Water Supply, Water Connection

Page 26

INSTALLATION INSTRUCTIONS - CONNECTIONS

Water Supply.

Where the water supply pressure exceeds 7 bar, an approved pressure reducing device is required at the inlet of the appliance. To achieve the maximum rated flow a minimum water supply pressure of 1.1 bar is required at the appliance inlet. The unit will operate at lower supply pressures but the maximum flow rate will not be achieved. Contact Rinnai or your supplier for 'gravity fed' or 'low pressure' hot water installations.

Water pipe sizing and layout should be designed correctly to ensure the given water flows from the appliance are available. All hot water pipework should be insulated to optimise maximum performance and energy efficiency.

Water Connection.

Connect the hot and cold water supply pipes as shown on the following page. An approved isolation valve and strainer MUST be installed in the cold water inlet pipe. An approved iso- lation valve and draining point should be installed in the hot water outlet pipe. There must be a union or release fitting on the heater side of the isolation valves. An unvented kit to lo- cal regulations must be installed in the pipework when the system is closed (i.e. has a flow and return, or tank.)

Positions of the cold water inlet, hot water outlet and gas connections are shown on page 41.

If the heater is in a hard water area a suitable water conditioning device should be installed to prevent the build up of limescale within the heat exchanger. Heat exchangers damaged by scaling are not covered by the manufacturer’s warranty.

Description

pH

Total Dissolved

Total Hardness

Chlorides

Magnesium

Calcium

Sodium

Iron

 

 

Solids (TDS)

 

 

 

 

 

 

Maximum Recommended

6.5 - 9.0

600 mg/litre

150 mg/litre

300 mg/litre

10 mg/litre

20 mg/litre

150 mg/litre

1 mg/litre

Levels

 

 

 

 

 

 

 

 

Gas Connection

Check pipe sizing required for the heater input. The gross heat input for the Infinity 16i is

34.9kW (G20); 29.6 kW (G25); 37 kW (G30, G31.) The size of the gas meter and pipework must be sufficient for all appliances on the main. Sufficient gas must be available at the appliance if correct operation is to be expected; insufficient gas will damage the unit. An approved gas isolation valve must be fitted at the gas inlet. A union or release fitting should be installed after the isolation valve.

Electrical Connection

The appliance must be earthed. The appliance is suitable for 230VAC – 50Hz mains only and all wiring must be carried out to local regulations.

26

Image 26
Contents Infinity 16 Page Contents Users Instructions Responsibilities of the UserFeatures and Benefits  Operating Noise Level is Very LOWImportant Information OFF Page Temperature Controls Suggested temperatures areTemperature Controls Operating ButtonsUsing the Temperature Controllers Adjusting TemperatureBathroom temperatures should be no more than 500C Switching the system onUsing hot water Page Temperature Controls Information Caring for the Infinity Error Messages Code Fault Remedy DisplayedWith temperature controller fitted Without temperature controller fittedRestarting the Rinnai Water Heater Standard systemInstallation Instructions StopUK Installation Instructions Important InformationPage Operation Principle HOT Water Supply OperationMain Components Main Components Installation Instructions Positioning Appliance LocationWater Connection Installation Instructions ConnectionsWater Supply Gas ConnectionUK INST. Instructions Connections MainsInstallation Instructions Schematics Single Infinity Direct FlowUK INST. Instructions Ventilation General InformationFlue Requirements Installing Flue LengthMuelink & Grol GroppalliUK Flue Requirements Installing UK Flue Requirements Positioning Temperature Controls Installation Page Page Page GAS Pressure Setting Page DIP Switch Setting Computer ProgrammingDimensions Technical Details InfinityFlow Chart Wiring Diagram Diagnostic Points MortorLetter of Compliance CE Certificate Commissioning Check List UK Warranty Standard UseSpecification Electrical Supply…………………………….…………..…………….….230V AC 50Hz 1phContact

REU - 16 FUA - E specifications

The Rinnai REU-16 FUA-E is a cutting-edge tankless water heater designed for efficiency and convenience. This model is part of Rinnai's renowned line of high-performance appliances, catering to both residential and commercial applications. It boasts a sleek design coupled with advanced technology that sets it apart in the crowded water heating market.

One of the most notable features of the REU-16 FUA-E is its impressive heating capacity. It is capable of delivering hot water on demand, with a maximum output of 16 liters per minute. This means you can comfortably run multiple hot water fixtures simultaneously without experiencing a drop in temperature or flow rate. Whether you’re taking a shower, running the dishwasher, or washing clothes, this unit meets the demand with ease.

The REU-16 FUA-E employs a state-of-the-art condensing technology, which enhances its efficiency by capturing and reusing some of the heat that would otherwise escape through the flue. This allows for an energy efficiency rating of up to 95%, significantly reducing energy bills and environmental impact compared to traditional storage water heaters.

Another key characteristic of this unit is its compact size. The Rinnai REU-16 FUA-E can be installed in smaller spaces, making it an ideal option for apartments, houses, or commercial properties with limited room for bulky tank units. Its flexibility in installation positions—whether indoors or outdoors—provides additional versatility to users.

Safety is also a primary concern with the REU-16 FUA-E. It comes equipped with numerous safety features, including an anti-freezing function, overheat protection, and venting safety controls. These safeguards ensure safe operation for you and your family, providing peace of mind whether it’s running constantly or in standby mode.

In terms of controls, the Rinnai REU-16 FUA-E offers modern digital displays that provide real-time monitoring of water temperature and status. This user-friendly interface makes it easier for homeowners or users to adjust settings according to their preferences.

Overall, the Rinnai REU-16 FUA-E encapsulates innovation and efficiency in water heating. Its combination of advanced technology, high performance, compact design, and safety features makes it a reliable choice for those seeking a consistent supply of hot water without the limitations of traditional systems. Whether for residential use or commercial applications, the REU-16 FUA-E is engineered to provide lasting performance and convenience.