Rinnai RCE-560PTR manual DXOWLQGLQJ3URFHGXUH, Qlwldo&Khfnv

Page 41

￿￿￿￿￿)DXOW￿)LQGLQJ￿3URFHGXUH

 

,QLWLDO￿&KHFNV

 

 

 

Service Call System

Check Points (No.’s refer to causes outlined in the following pages)

Appliance does not operate after

Check electrical cord is connected to the power point.

 

having pressed ON/OFF switch.

Confirm power supply.

 

(ON/Combustion indicator does

Check Function Lock (Indicator).

 

not illuminate green.)

 

 

 

Ignition does not occur.

Check gas hose is plugged in

1

(ON/Combustion Indicator

Check gas type matches that supplied to appliance.

 

does not illuminate red.)

Check gas hose isn’t bent/crimped

1

(Error code “11”)

Air in gas supply

1

No sparker noise even when

This appliance uses a muted sparker and makes a different

Heater ON/OFF button is

 

sound to older units.

 

pressed

 

 

 

Auto-economy indicator does

This appliance has an auto-economy function which automati-

not illuminate.

 

cally starts operating (“Economy” indicator illuminates) 30

 

 

minutes after a room reaches the set temperature. However,

 

 

the auto-economy function will not operate if the temperature

 

 

is set to L, 16, 26, or H.

 

Room does not warm up.

Check preset temperature

2

 

Blocked air filter

3

 

Warm air outlet short circuit (obstruction)

4

 

Inadequate gas supply

1

Flame Failure.

Insufficient ventilation

5

Error Code “12”

Blocked air filter

3

Error Code “14”

Power failure.

 

Error Code “00”*

Warm air outlet short circuit (obstruction)

4

 

Check gas type

 

 

Strong wind against appliance.

 

*When power is restored after

Inadequate gas supply (pipe bent/crimped)

1

power failure.

Reverse flame

7

There is a smell of gas.

Leaking gas supply (faulty connection)

1

 

Safety device operating.

 

 

Smell of combustion by-product

6

Air Purifier does not operate

Check electrical cord is connected to the power point.

 

when “Purif ON/OFF” button is

Confirm power supply.

 

pressed.

Loose primary filter. (Error code 05)

8

Dust sensor does not illuminate

Installation location (size of room)

 

red even if cigarette smoke is

Straight after power cord is connected.

 

present.

Y The dust indicator will illuminate green while the dust sensor is

 

 

stabilising (for approx. 1 min. after power re-instatement of for

 

 

approx 20 sec. after air purifier commences operation).

 

 

Dust sensor lens is dirty

9

Dust sensor indicator stays red.

Air in room is not clean.

 

Smoke and odours become hard

Filter is not clean

 

to remove from room.

 

(Clean the filter. If there is no change, replace with new

 

Heater becomes noisy.

 

filter.)

10

Convector 460/560PTR

- 36 -

©Rinnai

Image 41
Contents FAN Convector Convector RCE470/670TRE Key to Warning Symbols Table of Contents Glossary of Terms Development Background FeaturesIntroduction LPG SpecificationsNG, LPG Basic Combustion Specification Combustion SpecificationWarm Air Discharge Temperature Distribution 560PTR Heater Warm Air Discharge Velocity 560PTR Heater Warm Air Discharge Temperature Distribution 460PTR Heater Warm Air Discharge Velocity 460PTR Heater Air Discharge Velocity Air Purifier 460/560PTR Noise Level 460/560PTR Dimensions Installation Schematic Diagram Cut Away Diagram Control Panel Layout Operation PrinciplesClock Setting Temperature ControlSetting Timers 1 and 2 Heater Normal Heater OperationAutomatic-Economy Mode Heater Automatic Air Purifier Operation OFF Timer Air PurifierFilter Replacement Indicator Main Componentry Safety DevicesSensor Specification Valves Electrical Room Temperature Control DeviceOperating Principles CombustionConvector 460/560PTR Rinnai Operation/Comb. Ind Operational Flow ChartSV1 SV2 OFF Error Code Messages Error Code MessagesMemory Function for Maintenance Data 3520DWD Tto LPG DFWRU\0RGH Convector 460/560PTR Rinnai GND LDJQRVWLF3RLQWV7UDQVIRUPHU7HUPLQDO9ROWDJHV&RLO5HVLVWDQFHV QLWLDO&KHFNV DXOWLQGLQJ3URFHGXUHConvector 460/560PTR Rinnai Rqglwlrqvwkdwduhqrwidxowv $ $IWHUSUHVVLQJWKH+HDWHU212EXWWRQ DXOW$QDO\VLVMotor Coil Normal Value 150~300Ω No YES 7KHIODPHIDLOVGXULQJQRUPDORSHUDWLRQ $IWHUSUHVVLQJWKH$LU3XULILHU212EXWWRQ Convector 460/560PTR Rinnai DV&RQYHUVLRQ DV3UHVVXUH6HWWLQJ3URFHGXUH Lqvwuxfwlrqvehiruhhdfkhsodqdwlrq LVPDQWOLQJIRU6HUYLFLQJRemoval of the Purifier Filter Convector 460/560PTR Rinnai Roorzvhfwlrqedqgf Convector 460/560PTR Rinnai Removal of the Convection Fan Assy Removal of the Spark Electrode Convector 460/560PTR Rinnai Lulqjldjudp Orfnldjudp 7LPH&KDUWV Convector 460/560PTR Rinnai Convector 460/560PTR Rinnai Convector 460/560PTR Rinnai Convector 460/560PTR Rinnai Convector 460/560PTR Rinnai Convector 460/560PTR Rinnai Convector 460/560PTR Rinnai Convector 460/560PTR Rinnai 659,&&217$&732,176

RCE-560PTR specifications

The Rinnai RCE-560PTR is a leading model in the realm of energy-efficient water heating solutions, designed to meet the demands of modern households while providing exceptional performance. This innovative unit showcases a blend of advanced technology, user-friendly features, and durable construction, making it a top choice for both residential and commercial applications.

One of the hallmark features of the Rinnai RCE-560PTR is its tankless water heating capability. Unlike traditional water heaters that store hot water in a tank, this model heats water on demand, ensuring a continuous supply without the limitations of tank storage. This results in not only endless hot water but also enhanced energy efficiency, as the unit only operates when hot water is required. Consequently, users can experience significant energy savings and reduced utility bills.

The RCE-560PTR also incorporates Rinnai’s advanced technology, specifically the Circ-Logic system. This feature allows for the customization of recirculation patterns, facilitating faster water delivery and reducing wait times at the tap. Additionally, the unit is equipped with a built-in Wi-Fi module, enabling users to monitor and manage their water heating system remotely through a smartphone app. This level of connectivity ensures that households can maintain optimal performance and energy efficiency effortlessly.

Safety is a critical consideration in the Rinnai RCE-560PTR's design. The unit includes multiple safety features, such as an integrated temperature lock and a safety shut-off system, providing peace of mind to users. Furthermore, its durable construction features a stainless steel heat exchanger, ensuring longevity and resistance to corrosion, which contributes to the overall reliability of the product.

With an impressive flow rate, the RCE-560PTR can deliver up to 5.6 gallons per minute, making it suitable for larger homes or those with higher hot water demands. This feature, combined with its compact and sleek design, allows for flexible installation in various settings, from utility rooms to closets.

In summary, the Rinnai RCE-560PTR stands out in the market for its efficient tankless water heating technology, integrated smart features, safety-oriented design, and reliable performance. It represents a forward-thinking solution for consumers seeking to embrace sustainability while enjoying the comforts of modern living. With its combination of innovation and practicality, the RCE-560PTR is poised to redefine the future of water heating for homes and businesses alike.