Electrical Connection

The water heater must be electrically grounded in accordance with local codes or in the absence of local codes with the most recent edition of the National Electrical Code, ANSI/NFPA 70. In Canada, all electrical wiring should be in accordance with local codes and the Canadian Electrical Code, CSA C22.1 Part 1. Do not rely on the gas or water piping to ground the water heater. A screw is provided in the junction box for the grounding connection.

The water heater requires 120 VAC, 60 Hz power from a properly grounded circuit.

A disconnect switch must be provided and installed for the incoming 120 VAC power. It should be a type that is suitable for outdoor use. Check the National Electrical Code, ANSI/NFPA 70 and your local codes for a proper switch type to use in your area.

The wiring diagram is located on the Technical Sheet attached to the inside of the front cover.

T E R M I N A F O R C O N T R O

L S

L S

120V Wiring

black wire:Hot Leg white wire:Neutral

Ground

ONConnection

Screw

OFF

Gas Piping

General Instructions

Disconnect Switch

A manual gas control valve must be placed in the gas supply line to the Rinnai water heater. A union can be used on the connection above the shut off valve for the future servicing or disconnection of the unit.

Check the type of gas and the gas inlet pressure before connecting the Rinnai water heater. If the Rinnai water heater is not of the gas type that the building is supplied with, DO NOT connect the water heater. Contact the dealer for the proper unit to match the gas type.

Check the gas supply pressure immediately upstream at a location provided by the gas company. Supplied gas pressure must be within the limits shown in the Specifications section.

Before placing the appliance in operation all joints including the heater must be checked for gas tightness by means of leak detector solution, soap and water, or an equivalent nonflammable solution,

as applicable. (Since some leak test solutions, including soap and water, may cause corrosion or stress cracking, the piping shall be rinsed with water after testing, unless it has been determined that the leak test solution is non-corrosive.)

Always use approved connectors to connect the unit to the gas line. Always purge the gas line of any debris before connection to the water heater.

The gas supply line shall be gas tight, sized, and so installed as to provide a supply of gas sufficient to meet the maximum demand of the heater and all other gas consuming appliances at the location without loss of pressure.

Any compound used on the threaded joint of the gas piping shall be a type which resists the action of liquefied petroleum gas (propane / LPG).

Refer to an approved pipe sizing chart if in doubt about the size of the gas line.

VA Series Outdoor LS Manual

19

Image 19
Contents ANS Z21.10.3 CSA REU-VA2535WDTable of Contents R63LSe R75LSe R94LSe R98LSe SpecificationsSafety Definitions Consumer Safety InformationSafety Behaviors and Practices Safety Features Operating Instructions Features Available on Remote ControllersFeatures Description of OperationMC-91-1US & MCC-91-1US Remote Controllers ModelsBC-100V-1US Temperature Options Without a Remote Controller Setting the TemperatureModel Temperature Settings Available ºF Temperature RangesSetting the Sound Volume Voice Prompt Setting the ClockSetting the Water Volume Using the Water Smart / Bath Fill FunctionOverview Filling the Tub Setting Controller to MuteModels MC-91 and MCC-91 Maintenance Error Code Table Error CodesError Fault Remedy Code Accessing Operating Information Trouble Shooting for Common IssuesWater Quality Rinnai Water Heater Flushing the Heat Exchange Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceGas Piping Electrical ConnectionGeneral Instructions Pipe Sizing Procedure Example Pressure Relief Valve Water PipingFreeze Protection Rinnai Water Heater Freeze Protection PipingQTY Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsYears On Heat Exchanger Years On Parts Optional Piping for Circulation SystemsFlue Terminal Clearances ANS Z21.10.3 CSA Description Canadian Installations US Installations Additional Clearances Vent Terminal Guidelines High Altitude InstallationsConnecting Multiple Water Heaters Number of Connected Water Heaters Accessories NecessaryCable Lengths and Size Remote Controller InstallationConfigurations LocationOutline of Remote Mounting on the wallConnecting to the R63LSe Operating Instructions For Your Safety Read Before OperatingPressure Drop Curve Technical DataOutlet Flow Data Space Heating R63LSe, R75LSe, R94LSe R98LSe, R98LSe-ASME DimensionsHOT Ladder DiagramVA LS Series Period of Coverage from date of purchase Warranty InformationLimited Warranty Consumer SupportWhat will Rinnai do? Rinnai’s other fine products 103 International Drive

R75LSe, R94LSe, R63LSe, R98LSe specifications

The Rinnai R94LSe, R98LSe, R75LSe, and R63LSe are part of Rinnai's premier line of tankless water heaters, designed to provide on-demand hot water efficiently and sustainably. Each model caters to different household needs while offering advanced technologies and features.

The R94LSe boasts a maximum output of 9.4 GPM, making it ideal for larger households. It features a digital display that provides real-time information on temperature settings and performance. The R94LSe incorporates Circ-Logic technology, allowing users to set a schedule for hot water demands, ensuring instant access to hot water when needed. This model also employs a self-diagnostic system, which continually monitors performance and alerts users to any maintenance needs, helping extend the unit's lifespan.

The R98LSe is another powerful option with a maximum output of 9.8 GPM, perfect for homes with multiple bathrooms. It includes a remote control and a user-friendly interface, enhancing user experience. The R98LSe also features a unique indoor venting system, significantly reducing installation constraints, and is designed with energy efficiency in mind. This model's ultra-efficient heat exchanger provides consistent temperature control while minimizing energy consumption, fulfilling the growing demand for eco-friendly products.

For those seeking slightly less capacity, the R75LSe has a maximum output of 7.5 GPM, making it suitable for medium-sized homes. Similar to its counterparts, it utilizes Rinnai’s advanced technology to optimize energy usage. The R75LSe features an integrated freezing protection system and a compact design that allows for flexible installation options both indoors and outdoors.

The R63LSe is the smallest of the lineup, with an output of 6.3 GPM, making it ideal for smaller homes or apartments. Despite its compact size, it does not compromise on efficiency, offering advanced control options and energy-saving features. It includes a digital display for easy monitoring and can be equipped with an optional recirculation pump to enhance water availability.

Overall, the Rinnai R94LSe, R98LSe, R75LSe, and R63LSe models offer a range of capabilities suitable for various household sizes and hot water demands. These tankless water heaters exemplify innovation with their energy-efficient designs, advanced technologies, and ease of use, marking Rinnai as a leader in the market for reliable hot water solutions.