8. MAINTENANCE & TROUBLESHOOTING

6.4Error Message

The table below shows all the error messages which may appear.

Error message

Meaning

 

 

PLL1 Unlock

PLL circuit on the TX/RX pcb 05P0774 has unlocked.

 

 

PLL2 Unlock

PLL circuit on the DUP RX pcb 05P0777 has unlocked

 

(only FM-8800D).

 

 

ANT ERROR

The antenna is abnormal. In this condition, if the

 

transmission continues more than five seconds, the output

 

power is reduced to approximately 10W.

 

 

EPFS ERROR

There is no L/L input from a positioning sensor for more

 

than one minute.

 

 

System Error

The DSP (digital signal processor) is abnormally.

 

 

Printer PE

Printer is disconnected or paper runs out.

 

 

6.5Parts Location

Transceiver unit FM-8800D/8800S

PWR pcb

 

 

 

TX/RX pcb

 

 

 

05P0776

 

 

 

05P0774

DUPLEXER

 

 

 

 

FM-8800DFM-8800S

Top cover removed

PANEL pcb 05P0772

DUP RX pcb 05P0777

CH70 RX pcb

05P0775 CPU pcb

05P0773

FM-8800S/D

Bottom cover removed

6-3

Page 99
Image 99
Sunpentown Intl manual Error Message, Parts Location, Transceiver unit FM-8800D/8800S