A

Clearance above grade, veranda, porch,

12 inches (30 cm)

12 inches (30 cm)

deck, or balcony

 

 

 

 

 

 

 

 

 

B

Clearance to window or door that may be

36 inches (91 cm)

12 inches (30 cm)

opened

 

 

 

 

 

 

 

 

 

C

Clearance to permanently closed window

*

 

*

 

 

 

 

 

 

Vertical clearance to ventilated soffit,

 

 

 

D

located above the terminal within a

*

*

 

horizontal distance of 2 feet (61 cm) from

 

 

 

 

 

 

the center line of the terminal

 

 

 

 

 

 

 

 

E

Clearance to unventilated soffit

*

 

*

 

 

 

 

 

F

Clearance to outside corner

*

 

*

 

 

 

 

 

G

Clearance to inside corner

*

 

*

 

 

 

 

 

 

3 feet (91 cm) within a

 

H

Clearance to each side of center line

height 15 feet (4.5 m)

*

extended above meter/regulator assembly

above the meter/

 

 

 

 

regulator assembly

 

 

 

 

 

I

Clearance to service regulator vent outlet

36 inches (91 cm)

*

 

 

 

 

 

 

Clearance to nonmechanical air supply

 

 

 

J

inlet to building or the combustion air inlet

36 inches (91 cm)

12 inches (30 cm)

 

to any other appliance

 

 

 

 

 

 

 

 

 

 

 

 

3 feet (91 cm) above if

K

Clearance to a mechanical air supply inlet

6 feet (1.83 m)

within 10 feet (3 m)

 

 

 

 

horizontally

 

 

 

 

 

L

Clearance above paved sidewalk or

7 feet (2.13 m)

1

*

paved driveway located on public property

 

 

 

 

 

 

 

 

 

M

Clearance under veranda, porch, deck, or

12 inches (30 cm) 2

*

balcony

 

 

 

 

 

 

 

 

 

1A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

2Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

*For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the requirements of the gas supplier.

Flue Terminal Clearances (ANS Z21.10.3 CSA 4.3)

Image 27
Contents ANS Z21.10.3 CSA REU-VA3237W-ASMETable of Contents Model SpecificationsConsumer Safety Information Safety DefinitionsSafety Behaviors and Practices Safety Features Operating Instructions Features Available on Temperature ControllersFeatures Description of OperationMC-91-1US & MCC-91-1US Temperature Controllers ModelsBC-100V-1US Temperature Options Without a Temperature Controller Setting the TemperatureMCC-91 Temperature Controller Temperature RangesSetting the Sound Volume Voice Prompt Re-setting the Maximum TemperatureUsing the Water Smart / Bath Fill Function Setting the Water VolumeOverview Models MC-91 and MCC-91 Setting Controller to MuteSetting the Clock Filling the TubMaintenance Error Codes Error Code TableError Fault Remedy Code Trouble Shooting for Common Issues Accessing Operating InformationWater Quality Rinnai Water Heater Flushing the Heat Exchange Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceElectrical Connection Gas PipingGeneral Instructions Pipe Sizing Procedure Example Water Piping Pressure Relief ValveFreeze Protection Rinnai Water Heater Freeze Protection PipingQTY Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsYears On Heat Exchanger Years On Parts Optional Piping for Circulation SystemsFlue Terminal Clearances ANS Z21.10.3 CSA Description Canadian Installations US Installations Additional Clearances Vent Terminal Guidelines High Altitude InstallationsConnecting Multiple Water Heaters Number Connected Accessories NecessaryCable Lengths and Size Temperature Controller InstallationConfigurations LocationMounting on the wall Outline of Temperature controllerOperating Instructions For Your Safety Read Before OperatingTechnical Data Pressure Drop CurveOutlet Flow Data Pumps Temperature SettingReplacement Space HeatingR63LSe2, R75LSe, R94LSe R98LSe, R98LSe-ASME DimensionsHOT Ladder DiagramWarranty Information Limited WarrantyConsumer Support What will Rinnai do? Page Rinnai’s other fine products 103 International Drive

R63LSE2 specifications

The Rinnai R63LSE2 is a highly efficient and compact tankless water heater that offers an innovative solution for residential hot water needs. Designed with user convenience in mind, this model stands out for its performance, energy efficiency, and advanced technologies.

One of the main features of the R63LSE2 is its impressive flow rate, delivering up to 6.3 gallons per minute (GPM) of hot water. This capability allows households to enjoy simultaneous use of multiple fixtures, such as showers, sinks, and washing machines, without experiencing a drop in water temperature. This versatility makes the R63LSE2 an ideal choice for large families or homes with a high demand for hot water.

A key characteristic of the Rinnai R63LSE2 is its energy efficiency. It boasts a high Energy Factor (EF) rating, which translates to lower energy bills and reduced environmental impact. The unit utilizes an innovative heating technology that heats water on demand, eliminating the need for a storage tank. This approach not only conserves energy but also ensures a continuous supply of hot water.

In terms of technology, the R63LSE2 features advanced remote control capabilities, allowing users to monitor and adjust settings from anywhere in the home. This add-on capability enhances user experience and provides a level of convenience that is increasingly sought after in modern appliances. Additionally, the unit is equipped with state-of-the-art safety features, including a flame failure device, overheating protection, and a temperature control system, ensuring peace of mind during operation.

The Rinnai R63LSE2 is designed for easy installation and maintenance. Its compact size means it can be installed in various locations, including utility closets, garages, or even outdoor spaces, maximizing flexibility for homeowners. Furthermore, Rinnai provides comprehensive customer support and warranty options, ensuring assistance and reliability for users.

With a stylish design and durable construction, the R63LSE2 not only serves as a functional appliance but also complements the aesthetics of contemporary home designs. It represents a perfect combination of innovation, efficiency, and reliability for those seeking an effective water heating solution. Overall, the Rinnai R63LSE2 is an exceptional choice for anyone looking to upgrade their hot water system.