Rinnai R63LSE2 installation manual Water Piping, Pressure Relief Valve, Freeze Protection

Page 21

Water Piping

General Instructions

A manual water control valve must be placed in the water inlet connection to the Rinnai water heater before it is connected to the water line. Unions may be used on both the hot and cold water lines for future servicing and disconnection of the unit.

The piping (including soldering materials) and components connected to this appliance must be approved for use in potable water systems.

Purge the water line to remove all debris and air. Debris will damage the Rinnai water heater.

Pressure Relief Valve

Toxic chemicals such as those used for boiler water treatment are not to be introduced to the potable water used for space heating.

If the appliance will be used as a potable water source, it must not be connected to a system that was previously used with a nonpotable water heating appliance.

Ensure that the water filter on the Rinnai water heater is clean and installed.

An approved pressure relief valve is required by the American National Standard (ANSI Z21.10.3) / Canadian Standard (CSA 4.3) for all water heating systems.

The relief valve must comply with the standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems ANSI Z21.22 and/or the standard Temperature, Pressure, Temperature and Pressure Relief Valves and Vacuum Relief Valves, CAN1-4.4.

The relief valve must be rated up to 150 psi and to at least the maximum BTU/hr of the appliance.

The discharge from the pressure relief valve should be piped to the ground or into a drain system to prevent exposure or possible burn hazards to humans or other plant or animal life. Follow local codes. Water discharged from the relief valve could cause severe burns instantly, scalds, or death.

The pressure relief valve must be manually operated once a year to check for correct operation.

Freeze Protection

The freeze protection features include electrical heating elements and intermittent firing of the burner. Freeze protection may be disabled if electricity or gas is not supplied, or if there is an error preventing the water heater from functioning. Loss of freeze protection may result in water damage from a burst heat exchanger or water lines.

The installation of auto drain down solenoid valves is optional. However, Rinnai strongly recommends that these valves be installed to prevent damage from freezing in case the normal freeze protection should become disabled. Any product damage due to freezing will not be covered by the warranty.

In addition, the solenoid valves should be connected electrically to a surge protector with terminals. This allows the solenoid valves to operate if the water heater is disabled due to an error code.

The relief valve should be added to the hot water outlet line according to the manufacturer,s instructions. DO NOT place any other type valve or shut off device between the relief valve and the water heater.

Do not plug the relief valve and do not install any reducing fittings or other restrictions in the relief line. The relief line should allow for complete drainage of the valve and the line.

If a relief valve discharges periodically, this may be due to thermal expansion in a closed water supply system. Contact the water supplier or local plumbing inspector on how to correct this situation. Do not plug the relief valve.

Neither Rinnai nor the American National Standard (ANSI Z21.10.3) / Canadian Standard (CSA 4.3) requires a combination temperature and pressure relief valve for this appliance. However local codes may require a combination temperature and pressure relief valve.

The solenoid valves and surge protector with terminals are available for purchase at Rinnai.

Manually drain the water:

 

1.

Shut off cold water

 

 

 

 

 

 

supply.

 

 

 

 

 

 

 

 

 

 

 

2.

Open hot water tap

 

 

water filter

 

or open hot water

 

 

 

 

 

 

drain valve.

 

 

 

 

 

 

 

 

 

3.

Remove filter to

 

 

 

 

 

 

drain the cold

cold line

water.

 

VA Series Outdoor LS Manual

21

Image 21
Contents ANS Z21.10.3 CSA REU-VA3237W-ASMETable of Contents Model SpecificationsConsumer Safety Information Safety DefinitionsSafety Behaviors and Practices Safety Features Features Features Available on Temperature ControllersDescription of Operation Operating InstructionsMC-91-1US & MCC-91-1US Temperature Controllers ModelsBC-100V-1US Temperature Options Without a Temperature Controller Setting the TemperatureSetting the Sound Volume Voice Prompt Temperature RangesRe-setting the Maximum Temperature MCC-91 Temperature ControllerUsing the Water Smart / Bath Fill Function Setting the Water VolumeOverview Setting the Clock Setting Controller to MuteFilling the Tub Models MC-91 and MCC-91Maintenance Error Codes Error Code TableError Fault Remedy Code Trouble Shooting for Common Issues Accessing Operating InformationWater Quality Rinnai Water Heater Flushing the Heat Exchange Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceElectrical Connection Gas PipingGeneral Instructions Pipe Sizing Procedure Example Water Piping Pressure Relief ValveFreeze Protection Rinnai Water Heater Freeze Protection PipingQTY Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsYears On Heat Exchanger Years On Parts Optional Piping for Circulation SystemsFlue Terminal Clearances ANS Z21.10.3 CSA Description Canadian Installations US Installations Additional Clearances Vent Terminal Connecting Multiple Water Heaters High Altitude InstallationsNumber Connected Accessories Necessary GuidelinesConfigurations Temperature Controller InstallationLocation Cable Lengths and SizeMounting on the wall Outline of Temperature controllerOperating Instructions For Your Safety Read Before OperatingTechnical Data Pressure Drop CurveOutlet Flow Data Replacement Temperature SettingSpace Heating PumpsR63LSe2, R75LSe, R94LSe R98LSe, R98LSe-ASME DimensionsHOT Ladder DiagramWarranty Information Limited WarrantyConsumer Support What will Rinnai do? Page Rinnai’s other fine products 103 International Drive

R63LSE2 specifications

The Rinnai R63LSE2 is a highly efficient and compact tankless water heater that offers an innovative solution for residential hot water needs. Designed with user convenience in mind, this model stands out for its performance, energy efficiency, and advanced technologies.

One of the main features of the R63LSE2 is its impressive flow rate, delivering up to 6.3 gallons per minute (GPM) of hot water. This capability allows households to enjoy simultaneous use of multiple fixtures, such as showers, sinks, and washing machines, without experiencing a drop in water temperature. This versatility makes the R63LSE2 an ideal choice for large families or homes with a high demand for hot water.

A key characteristic of the Rinnai R63LSE2 is its energy efficiency. It boasts a high Energy Factor (EF) rating, which translates to lower energy bills and reduced environmental impact. The unit utilizes an innovative heating technology that heats water on demand, eliminating the need for a storage tank. This approach not only conserves energy but also ensures a continuous supply of hot water.

In terms of technology, the R63LSE2 features advanced remote control capabilities, allowing users to monitor and adjust settings from anywhere in the home. This add-on capability enhances user experience and provides a level of convenience that is increasingly sought after in modern appliances. Additionally, the unit is equipped with state-of-the-art safety features, including a flame failure device, overheating protection, and a temperature control system, ensuring peace of mind during operation.

The Rinnai R63LSE2 is designed for easy installation and maintenance. Its compact size means it can be installed in various locations, including utility closets, garages, or even outdoor spaces, maximizing flexibility for homeowners. Furthermore, Rinnai provides comprehensive customer support and warranty options, ensuring assistance and reliability for users.

With a stylish design and durable construction, the R63LSE2 not only serves as a functional appliance but also complements the aesthetics of contemporary home designs. It represents a perfect combination of innovation, efficiency, and reliability for those seeking an effective water heating solution. Overall, the Rinnai R63LSE2 is an exceptional choice for anyone looking to upgrade their hot water system.