2.5 Pre-Installation

DANGER

No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster/Dean Service Hotline at 1-800-551-8633.

DANGER

Do not connect this appliance to the gas supply before reviewing all information in

this chapter.

A.General: Only licensed personnel should install any gas-fired equipment.

1.A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for safety and ease of future service.

2.Dean Super Marathon Series gas fryers operate on millivolts, and do not require an external electric power supply (unless equipped with built-in filtration system).

B.Clearances: The fryer area must be kept free and clear of all combustibles. This unit is design- certified for the following installations:

1.Commercial installation only (not for household use).

2.Non-combustible floor installation equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch (13-cm) casters;

3.Combustible construction with a minimum clearance of 6-inches (15-cm) side and 6-inches (15-cm) rear, and equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch

(13-cm) casters.

DANGER

Local building codes prohibit a fryer with its open tank of hot oil from being installed

beside an open flame of any type, including those of broilers and ranges.

2-3