DEAN MILLIVOLT GAS FRYERS
CHAPTER 3: INSTALLATION INSTRUCTIONS
3.4 Gas Connections (cont.)
WARNING
Use a diluted soap solution to find potentially dangerous gas leaks when making
new connections.
B.Regulators: Gas regulators can be adjusted in the field, but no adjustments should be made unless the regulator is out of adjustment, or serious pressure fluctuations are observed.
C.Only qualified service personnel should make adjustments to the regulators.
D.Orifices: The fryer can be configured to operate on any available gas. The correct safety control valve, appropriate gas orifices, and pilot burner are installed at the factory. While the valve can be adjusted in the field, only qualified service personnel should make any adjustments with the proper test equipment.
E.Flexible Couplings, Connectors and Casters
1.If the fryer is to be installed with flexible couplings and/or
2.For an appliance equipped with casters, the installation shall be made with a connector that complies with local codes or in the absence of local codes, with the appropriate national standards.
3.Under no circumstances are the connector and the
WARNING
Do not attach accessories to this fryer unless fryer is secured from tipping.
Personal injury may result.
4.To limit movement of the fryer, restraints independent of the flexible coupling or connector must be used. Clips are located on the back panel of the fryer for the attachment of restraints.
5.If disconnection of the restraint is necessary, the restraint must be reconnected after the fryer has been returned to the position it was originally installed.