DEAN MILLIVOLT GAS FRYERS
CHAPTER 3: INSTALLATION INSTRUCTIONS
3.6 Gas Inputs
Nominal Heat Inputs (Qn), Gas Type, Orifice Size (applicable for fryer operation at altitudes of 2000 feet or less), Part Number and Quantity are listed in the table below:
MODEL | NOMINAL HEAT | GAS TYPE | ORIFICE SIZE | ORIFICE | ORIFICE | |
| INPUT- Qn |
| (MM) | PART NO. | QUANTITY | |
| (BTU) |
|
|
|
| |
SM 80 GM | 165 | NAT | 2.58(#38) | 5 | ||
LP | 1.61(#52) | 5 | ||||
|
| |||||
|
|
|
|
|
| |
SM 60 GM | 150 | NAT | 2.53(#39) | 5 | ||
LP | 1.51(#53) | 5 | ||||
SR 62G | ||||||
| LP | 1.61(#52)** | 5 | |||
|
| |||||
|
|
|
|
|
| |
SR 52 GM | 120 | NAT | 2.53(#39) | 4 | ||
SM 50 GM | LP | 1.51(#53) | 4 | |||
| ||||||
|
|
|
|
|
| |
SM 35 GM | 105 | NAT | 2.80(#35) | 3 | ||
SR 42G | LP | 1.70(#51) | 3 | |||
| ||||||
|
|
|
|
|
| |
SM 20 GM | 50 | NAT | 2.18(#44) | 2 | ||
LP | 1.40(#54) | 2 | ||||
|
| |||||
|
|
|
|
|
|
* Use these orifices on SR42 fryers built after 4/07. ** Use these orifices for Australian units.
A. Adjustments for different gases are as follows:
Gas Adjustments
Gas Type | Natural | LP | |
|
|
| |
Gas Supply Pressure* | 4" W.C. (10 mbars) | 11" W.C. (27.5 mbars) | |
|
|
| |
Orifice Diameter | See Table Above. | See Table Above. | |
|
|
| |
Burner Marking | None | None | |
|
|
| |
Pilot Marking | 26N | 16LP | |
|
|
| |
Gas pressure at the regulator | 4" W.C. (10 mbars) | 11" W.C. (27.5 mbars) | |
[Inches W.C. (mbar)]* | |||
|
|
NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating.