Stovax 8627 MA, 8627 BS manual Appliance Commissioning Checklist, Flue Check, Pass Fail, Gas Check

Page 3

APPLIANCE COMMISSIONING CHECKLIST

IMPORTaNT NOTICE

Explain the operation of the appliance to the end user, hand the completed instructions to them for safe keeping,

as the information will be required when making any guaranteed claims.

FLUE CHECK

 

 

Pass

Fail

 

 

 

 

 

 

1.

Flue is correct for appliance

 

 

 

 

 

 

 

 

 

 

2.

Flue flow test N/A

 

 

 

 

 

 

 

 

 

 

3.

Spillage test N/A

 

 

 

 

 

 

 

 

 

GAS CHECK

 

 

 

 

 

 

 

 

 

 

1.

Gas soundness & let by test

 

 

 

 

 

 

 

 

 

 

2.

Standing pressure test

 

 

mb

 

 

 

 

 

 

 

3.

Appliance working pressure (on High Setting)

 

 

mb

 

 

NB All other gas appliances must be operating on full

 

 

 

 

 

 

 

 

 

 

4.

Gas rate

 

 

m3/h

 

5.

Does ventilation meet appliance requirements N/A

 

 

 

 

 

 

 

 

 

 

6.

Have controls been upgraded (Upgradeable models only)

8455 Standard

YES

NO

 

 

 

 

 

 

8456 Programmable Thermostatic and Timer

YES

NO

 

 

 

 

 

 

 

 

 

 

 

 

DEALER AND INSTALLER INFORMATION

Dealer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contact No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Date of Purchase. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Serial No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gas Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation Company . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Engineer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contact No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Corgi Reg No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Date of Installation . . . . . . . . . . . . . . . . . . . . . . . . . . .

This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Gazco and your local Gazco dealer. This guarantee will be invalid, to the extent permitted by law, if the above Appliance Commissioning Checklist is not fully completed by the installer and available for inspection by a Gazco engineer. The guarantee will only be valid during the second year, to the extent permitted by law, if the annual service recommended in the Instructions for Use has been completed by a Corgi registered engineer, and a copy of the service visit report is available for inspection by a Gazco engineer.

3

Image 3
Contents Riva Nemos Contents GAS CHECK APPLIANCE COMMISSIONING CHECKLISTFLUE CHECK Pass FailTurning the Nemos off User InstructionsGeneral Lighting the NemosArrangement of Fuel BED Components Cleaning the NemosPlace log G at the front of the fire between logs D and E HOT SURFACES MA P8627 MA BS P8627 BS Installation InstructionsTechnical Specification Packing ChecklistFlue and Chimney Requirements SITE REQUIREMENTSFlue Options TOP Flue UP & OUT KIT 8534/8534ANTOP Flue UP & OUT with Additional Bend GAS Supply TOP Flue Vertical KIT 8524/8524ANTOP Flue Vertical Offset KIT Optional Flue Lengths & BendsInstallation of the appliance InstallationControl upgrade Safety PrecautionsAR1290/1 AR1293 AR1294 Centralise the LOG Between the Burnerports AT Either END FITTING THE DOOR Commissioning Servicing / Fault Finding Charts Servicing InstructionsServicing Requirements Flame Failure Functional Check Ignition Functional CheckReplacing Parts GeneralMain Burner Pilot Unit IGNITION LEAD PiezoGAS Valve Magnetic Safety Valve Main InjectorPrimary Aeration Plate ShoRt Spares List Changing between Gas TypesService Records Page Member of the Stovax Group

8627 MA, P8627 MA, P8627 BS, 8627 BS specifications

Stovax, a renowned name in the fireplace and wood-burning stove industry, has introduced the P8627 series, which includes models P8627 MA and P8627 BS. These products represent a marriage of innovative technology and traditional design, appealing to both modern and classic aesthetics while ensuring high efficiency and performance.

One of the standout features of the P8627 series is its exceptional heat output. These models are engineered to maximize warmth while minimizing fuel consumption, making them an environmentally friendly choice for homeowners. The high-efficiency ratings are complemented by the advanced combustion system that enhances fuel burning, ensuring that more of the wood's energy is converted into heat rather than wasted as smoke.

The P8627 MA model, with its minimalist design and large viewing window, provides an unobstructed view of the fire, creating a warm, inviting ambiance in any living space. It boasts a clean burn technology that significantly reduces emissions, making it an ideal option for eco-conscious consumers. The model's adjustable air control allows users to regulate the burn rate, providing flexibility in how quickly or slowly the fire burns.

On the other hand, the P8627 BS model features a more robust casing, offering added durability while maintaining an elegant appearance. This model also utilizes secondary combustion technology to improve efficiency and reduce particulate emissions. Both models have been tested to comply with stringent environmental standards, ensuring they are safe and efficient for use.

An additional characteristic of the P8627 series is their versatility in installation options. They can be fitted into various settings, whether it be a traditional or contemporary home. With the ability to connect to different flue systems, Stovax ensures that these stoves can accommodate diverse layouts and individual home requirements.

Furthermore, both models are designed with user convenience in mind. The easy-to-use controls, combined with a clean glass design that reduces soot buildup, make maintenance hassle-free. The stylish design options allow homeowners to integrate the stoves seamlessly into their living spaces, enhancing overall aesthetics without compromising functionality.

In summary, the Stovax P8627 MA and P8627 BS models stand out for their efficiency, eco-friendliness, and design versatility. With advanced technologies and user-friendly features, they are an excellent choice for anyone looking to add a reliable and stylish heating solution to their home.