Napoleon Grills WF 6, WF9ST, WF 18, WF 9 manual Cleaning And Maintenance

Page 6
CLEANING AND MAINTENANCE

WF6

 

WF9

 

WF18

BACKBOARD

BACKBOARD

BACKBOARD

 

 

 

 

 

 

35.250”

MORTAR

35.250”

 

 

MORTAR

 

 

 

 

TILES

TILES

 

 

 

 

 

 

70.50”

23.625”

 

35.50”

 

 

MORTAR

 

CUSTOM SURFACE PANEL: Panels can also be made using materials such as mirror,

 

 

 

glass, slate, marble or ceramic tile for display in your waterfall. If tiling, use waterproof cement

 

 

board as a backer, available at any building centre. Cut the cement board to the size of your

TILES

 

existing stainless steel panel. Ensure that the tiles can be used in a wet environment. Porce-

 

 

 

lain tiles are recommended. Tile the surface, using thinset mortar, as you would a ceramic tile

 

 

floor or bathroom wall. It is not necessary to leave a gap or grout line in your tile. Ensure that the

35.50”

bottom edge of the tiles are flush with the bottom edge of the cement board. You can choose any colour

 

or pattern that you like, to match the room or surroundings. The water will flow over the tiles, just as it does on the stainless steel panel, but be sure to keep the edges of the tiles fairly flush to each other to prevent the water from splashing off. Surfaces less than 3/8” thick, such as glass or mirror, can be installed in front of the stainless panel. The stainless panel must be removed for all panels thicker than 3/8” up to a maximum of 3/4”. Do not use glue to attach the tiles to the back panel, as some types of glue or epoxy will leach out into the water, causing the filter and manifold to plug.

CLEANING AND MAINTENANCE

The waterfall should be drained and cleaned every 3-4 months, possibly more depending on the quality of the water. The water- fall surface can be cleaned using a warm soap and water mixture. Do not use harsh abrasive cleaners on the surface of the stainless steel panel or it will permanently scratch the surface. Any wiping motion should be done in the direction of the grain. If small scratches do occur, they can be blended out by gentle rubbing in the direction of the grain with a Scotchbrite pad.

The water should be completely flushed and drained from the system - switch the valve to the purge setting, and run the pump to pump the water out. Refill the tank, run the water through the fountain for 3 minutes and purge again. If calcium or hard water deposits are forming on the panel or anywhere else in the system, cycle CLR solution through the system until the deposits are removed then purge the system a few times with water.

TO FOUNTAIN

FROM BASIN

If there are spots on the panel that dry out, check that there are no blocked ports in the manifold tube. Remove the three nuts that secure the tube cover, and remove the cover. Re- move the tube by flexing it out in the centre. This will allow the ends to pull out. Poke the holes out with an opened paper clip, and then flush the tube with water. Clean the angled surface that the manifold sprays onto with liquid TSP (or TSP substitute). It is critical that this surface is extremely clean. Install the tube back into the unit, with the ports aiming straight down and refill with water. Install the tube cover and test the unit.

TO DRAIN

VALVE

PURGE POSITION

MANIFOLD TUBE

TUBE COVER

The sediment filter should be replaced every 3-4 months. To replace, unplug the pump. Lay a towel under the filter housing, as water will drain out of the housing when opening. Unscrew the housing, and remove the filter. Replace with a new filter (part #N252-0001) available through your authorized NAPOLEON dealer. Push the new sediment filter firmly onto the collar in the bottom of the housing. Screw the housing back onto the unit. This must be screwed on very tightly, or it will leak.

6

Image 6
Contents DECORATIVE INDOOR WATERFALLS WF 6/9/18 WF9STSERIAL / SÉRIE# THAT PURIFY AND HUMIDIFY THE AIRNAPOLEON WATERFALL PRESIDENTS WARRANTY CONDITIONS AND LIMITATIONSinstallation Tools and materials required indoor air qualityappropriate location water WATER PUMPSELECTRICAL REQUIREMENTS INSTALLATION WATERFALL SURFACE MATERIALSCLEANING AND MAINTENANCE Solution TROUBLESHOOTINGProblem Possible CausesORDERING REPLACEMENT PARTS FRAMING SPECIFICATIONS PIPING DIAGRAM WITHOUT UV LIGHT 6 N570-0043 8-32X 3/4PIPING DIAGRAM WITH UV-LIGHT 9 N570-0043 8-32X 3/4WATERFALL SURFACE INSTALLATION PARTS LISTPARTS DIAGRAM