Verilux VH07 manual Care and Maintenance, Cleaning the Inlet, Emptying the Collection Cup

Page 10

Care and Maintenance

Cleaning the Inlet

If the inlet is blocked by dust, completely remove the foreign materials – after first turning the vacuum OFF.

A blocked inlet may result in weakened suction and noise. If the inlet is blocked, there is also a risk of damage or malfunction caused by overheating.

Emptying the Collection Cup

Inlet

 

1.Disconnect the handheld vacuum cleaner from the base unit by pressing the release lever at the rear of the base unit and lifting up.

2.Press the collection cup lock button to

release the collection cup from the vacuum (see Figure 3).

3.Carefully pull the filter assembly outward and remove (see Figure 4).

Collection Cup

Lock Button

4. Empty the cup.

Figure 3

Cleaning the Filters

5.Unlock the outer filter by twisting it slightly to the right, clockwise (see Figure 5).

6.Remove the outer filter by pulling it away from the main casing.

7.Pull the inner filter out to remove.

8.The filters should be cleaned every time the collection cup is emptied by tapping them on the side of the collection cup to release trapped dust.

9.Wash both filters in lukewarm water on a regular basis.

10.Make sure the filters are completely dry before reassembly.

11.Reassemble in the reverse order.

Filter Collection

Assembly Cup

Figure 4

Figure 5

Outer Filter

Inner Filter

10

Image 10
Contents VH07 Page Table of Contents Important Safety Instructions Important Safety Instructions -­ Introduction What’s IncludedCleanWave Sanitizing Furniture & Bed Vac Features Description of FunctionsInitial Set-up Using the Handheld Vacuum OnlyVacuuming with UV-C Mattress / Bedding Cleaning Guidelines Cleaning the Filters Care and MaintenanceCleaning the Inlet Emptying the Collection CupCleaning the UV-C Bulb Avoiding Exposure to DustReplacing the UV-C Bulb Poor Suction TroubleshootingSafety Switches UV-C Light is Not IlluminatedTechnical Specifications One Year Limited Warranty VH07-MAN-Rev16