Honeywell 2000B manual Night mode very bright, no alarms, Possible Cause K2 relay open

Page 7

FlashGuard 2000B Troubleshooting Guide

Section 7 Flashhead flashing slow (15 – 20 flashes per minute), strobe alarm on.

Possible Cause: Mis-configured or defective sync monitor board.

Diagnostic Test: Ensure the DIP switches on the sync monitor board are set correctly per the manual. Visually verify that the red LED on the sync monitor board is pulsing at 40 fpm.

Corrective Action: If the DIP switch settings are correct, and the red LED is not pulsing at 40 fpm, replace the sync monitor board.

Possible Cause: Current sense transformer wires are crossed, or current sense transformer is defective.

Diagnostic Test: The brown wire should connect to the capacitor side of the current sense transformer, the purple wire towards TB2.

Corrective Action: If the transformer wires are correct, replace the current sense transformer.

Section 8 Night mode very bright, no alarms.

Possible Cause: K2 relay open.

Diagnostic Test: Put the system in night mode. Check for 120 VAC across the coil of the K2 relay. Alternatively, remove the connectors and check resistance across the K2 coil – it should be @ 300Ω.

Corrective Action: Replace the K2 relay.

MULTIPLE STROBE PROBLEMS

Section 9 Flashheads are operating, but out of sync.

Possible Cause: Sync monitor boards in the power supplies not configured correctly.

Diagnostic Test/ Corrective Action: Configure sync board as referenced in manual.

Possible Cause: Interconnecting wire between master and slave power supplies missing.

Diagnostic Test: Inspect wiring between power supplies. TB1 position 3 should be daisy- chained between each power supply, per the installation wiring diagram.

Corrective Action: Install interconnecting wiring.

Page 7

Image 7
Contents Page FlashGuard 2000B Troubleshooting Guide Flashhead Strobe ProblemsStart Multiple Strobe ProblemsPossible Cause Diagnostic TestCorrective Action Replace DB1 Corrective Actions Possible Cause K2 relay open Night mode very bright, no alarmsFlashGuard 2000B Troubleshooting Guide Flashhead Test Results Flashhead Isolation TestObserve Neon Lamp Power Supply Isolation TestVoltage Measurements FG 2000B MeasurementsTools Required Status IndicatorsRecommended Spare Parts Power Supply Spares DownstairsFlashhead Spares Upstairs FlashGuard 2000B Troubleshooting Guide