FlashGuard 2000B Troubleshooting Guide
Section 10 All lights are in sync, but there is a
Possible Cause: More than one sync monitor board is set as master.
Diagnostic Test: Inspect the DIP switches on each sync monitor board. In the master power supply, DIP switch
Corrective Action: Reconfigure sync monitor boards. Refer to the manual for correct positions.
Section 11 Master unit switches to night mode at night, but slave units remain in day mode.
Possible Cause: Interconnecting wire between master and slave power supplies missing.
Diagnostic Test: Inspect wiring between power supplies. TB1 position 1 should be daisy- chained between each power supply, per the installation wiring diagram for multiple units. Note: Do not interconnect
Corrective Action: Install interconnecting wiring.