Honeywell manual FlashGuard 2000B Troubleshooting Guide

Page 8

FlashGuard 2000B Troubleshooting Guide

Section 10 All lights are in sync, but there is a double-flash, or flashing faster than 40 flashes per minute (fpm).

Possible Cause: More than one sync monitor board is set as master.

Diagnostic Test: Inspect the DIP switches on each sync monitor board. In the master power supply, DIP switch S1-4 should be set to “OFF,” which is the master position. In all the other power supplies, this switch 4 should be set to “ON,” which is the slave position

Corrective Action: Reconfigure sync monitor boards. Refer to the manual for correct positions.

Section 11 Master unit switches to night mode at night, but slave units remain in day mode.

Possible Cause: Interconnecting wire between master and slave power supplies missing.

Diagnostic Test: Inspect wiring between power supplies. TB1 position 1 should be daisy- chained between each power supply, per the installation wiring diagram for multiple units. Note: Do not interconnect TB1-2 between power supplies.

Corrective Action: Install interconnecting wiring.

Page 8

Image 8
Contents Page Flashhead Strobe Problems FlashGuard 2000B Troubleshooting GuideMultiple Strobe Problems StartDiagnostic Test Possible CauseCorrective Action Replace DB1 Corrective Actions Night mode very bright, no alarms Possible Cause K2 relay openFlashGuard 2000B Troubleshooting Guide Flashhead Isolation Test Flashhead Test ResultsPower Supply Isolation Test Voltage MeasurementsFG 2000B Measurements Observe Neon LampStatus Indicators Tools RequiredFlashhead Spares Upstairs Power Supply Spares DownstairsRecommended Spare Parts FlashGuard 2000B Troubleshooting Guide