Install the pop-up drain (18210001 only)
Remove the plunger assembly.
Unscrew the drain outlet flange from the tee.
Unscrew the tailpiece from the tee. Wrap the threads with plumbers’ thread tape and replace.
Install the white, flexible sealing gasket to the flange. Place it in the sink outlet.
From under the sink, install the black mack gas- ket, white friction ring and retainer nut to the flange. Do not tighten the nut against the bottom of the sink at this time.
Thread the tee and tailpiece to the flange. The pivot must face the faucet. If necessary, turn the drain assembly.
Tighten the retainer nut. | pull rod |
Place the plunger assembly in the drain.
Install the horizontal rod so that the end goes through the loop in the bottom of the height adjuster.
Install and hand tighten the pivot ball nut.
Attach the swivel connector to the end of the horizontal rod.
plunger
height adjuster
flange
sealing gasket
mack gasket
friction ring
retainer nut
tee
pivot ball nut
Attach the swivel connector to the end of the
pull rod. Position as desired and tighten with ahorizontal rod small, flathead screwdriver.
swivel connector