English
Single Control Lavatory Faucet
Solaris² E | 04167XX0 |
Allegro² E | 04180XX0 |
Metro² E | 04193XX0 |
Solaris² E | Allegro² E | Metro² E |
04167XX0 | 04180XX0 | 04193XX0 |
Technical Information
Recommended water pressure | 14.7 - 72.5 psi |
Recommended hot water temp. | 120� - 140� F* |
Max. hot water temp | 165�F* |
Hole size in mounting surface | |
Max. mounting surface depth | 1 5/8” |
Flow rate | .2 gpm |
M3 Cartridge with high temperature limit stop |
|
3/8” supply hoses - requires 3/8” compression fitting (not included)
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater.
Installation Considerations
•For best results, Hansgrohe recommends that this unit be installed by a licensed, profes- sional plumber.
•Please read over these instructions thoroughly before beginning installation. Make sure that you have all tools and supplies needed to complete the installation.
•The high temperature limit stop may be reset, if desired.