Hans Grohe 04167XX0, 04193XX0 English Reset the High Temperature Limit Stop optional

Page 6

English

Reset the High Temperature Limit Stop (optional)

Use a 4 mm Allen wrench to push the screw cover into the handle

Use the 4mm Allen wrench to loosen the handle screw 4 complete revolutions. Remove the handle.

Remove the nut cover.

Remove the handle screw from the stem of the cartridge.

Remove the high temperature limit stop.

Replace the high temperature limit stop so that the pin on the cartridge is in the desired slot on the limit stop. Note: the temperatures given in the diagram assume a water heater temperature of 140° F, a cold water temperature of 50° F and a water pressure of 45 PSI.

Replace the nut cover. Replace the handle screw. Use the Allen wrench to turn the screw 4 revolutions.

Replace the handle. Finish tightening the handle screw. Turn on the water and test the faucet.

Image 6
Contents Installation Instructions / Warranty Installation Considerations EnglishTechnical Information English Installation English Install the pop-up drain English Reset the High Temperature Limit Stop optional Prendre en considération pour l’installation FrançaisDonnées techniques Français Installation Français Français Installation de l’obturateur à clapet Français Réglage de la butée limite d’eau chaude en option Replacement Parts Cleaning Recommendation for Hansgrohe Products Recommandations pour le nettoyage des produits HansgroheLimited Lifetime Consumer Warranty Instructions de nettoyage pour robinetteries et douchesTo Obtain Warranty Parts or Information US Installation Instructions Part No -01 Revised 03/2008