Temperature and Humidity Ranges
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.
MODE | OPERATING CONDITIONS | IF OUT OF CONDITIONS | |
| Indoor temp: 16°C~32°C | - A safety device will stop continuously the | |
| system functioning; | ||
|
| ||
COOL | Indoor humidity: below 80% | ||
- Condensation may occur on the indoor unit | |||
| Outdoor temp: 21°C~43°C | with risk to have either water blow off or drops | |
| on the floor; | ||
|
| ||
HEAT | Indoor temp: below 27°C | - A safety device will stop continuously the | |
| |||
Outdoor temp: 0°C~24°C | system functioning; | ||
| |||
|
| ||
|
|
| |
| Indoor temp: 16°C~32°C | - A safety device will stop continuously the | |
| system functioning; | ||
|
| ||
DRY | Indoor humidity: below 80% | ||
- Condensation may occur on the indoor unit | |||
| Outdoor temp: 18°C~43°C | with risk to have either water blow off or drops | |
| on the floor; | ||
|
| ||
POWER SUPPLY | Single phase rated voltage | ||
minimum and maximum limit | 198V | ||
|
Any damage occurs out of condition specified cannot be covered by product warranty.
If the system works continuosly outside of conditions, its performace and reliability will be compromised.
Operating Recommendations
When you use your air conditioner, it is recommended that you read the following:
Topic | Recommendation |
|
|
Heating capacity | The heat pump inside the air conditioner absorbs heat from outside air and brings itindoors. |
| If the temperature of the outside air drops, the air conditioner heats less. If the room is not warm |
| enough, use an additional heating appliance. |
|
|
Warm air circulation | The air conditioner circulates warm air to heat your room. It will take some time to warm |
| the air in your room entirely after the air conditioner turns on. |
| Therefore, turn the air conditioner on in advance. |
|
|
Frost | When you select the Heat mode, frost may form in the outdoor unit due to low temperature |
| and high humidity. |
| If this happens: |
| The heating operation is stopped. |
| The air conditioner defrosts automatically for about 7 minutes. After about 7 minutes, |
| the air conditioner starts operating again normally. |
|
|
High indoor and | If both the indoor and outdoor temperatures are high when you select the Heat mode, |
outdoor temperatures | the fan and the compressor of the outdoor unit may stop periodically. |
| This is normal; wait until the air conditioner turns on again. |
|
|
Power failure | If a power failure occurs when the air conditioner is operating, the air conditioner will turn off. |
| When the power returns, the air conditioner will start up again automatically. |
|
|
Protection mechanism | When the air conditioner is started immediately after being plugged in or stopped, |
| the normal operation starts up after 3 minutes for the reason of protection. |