Samsung LF-NBNHNN/EN manual IPv6 Tab, Enable IPv6, Link Local Address, Enable DHCPv6

Page 36

2Using "PCoIP"

You should always set the Ethernet Mode to Auto and only use 10 Mbps Full Duplex or 100 Mbps Full Duplex when the other network equipment (i.e., switch) is also configured to operate at 10 Mbps full-duplexor 100 Mbps full-duplex. An improperly configured Ethernet Mode may result in the network operating at half-duplex which is not supported by the PCoIP protocol. The session will be severely degraded and eventually dropped.

IPv6 Tab

The IPv6 page lets you enable IPv6 for PCoIP devices connected to your IPv6 network.

z

z

IPv6 is not currently supported by VMware View.

When you make a change to one of the settings on this page, you must reboot your device for the change to take effect.

Figure 2-6: IPv6 Configuration

z

z

z

z

z

Enable IPv6

Enable this field to enable IPv6 for your PCoIP devices.

Link Local Address

This field is automatically populated.

Gateway

Enter the gateway address.

Enable DHCPv6

Enable this field to set up Dynamic Host Configuration Protocol version 6 (DHCPv6) for your device. Primary DNS

The primary DNS IP address of the device. If DHCPv6 is enabled, this field is automatically populated by the DHCPv6 server.

2 Using "PCoIP" 36

Image 36
Contents NB-NH Table Of Contents Index Symbols for safety precautions CopyrightIcons used in this manual Safety Precautions Electricity and SafetyInstallation and Safety Before Using the Product Operation and Safety GAS Before Using the Product Before Using the Product Checking the Contents PreparationsChecking the Components ComponentsItems sold separately Parts ButtonReverse Side Ports DescriptionRight Side View Installation ReassemblyPreparations Adjusting the Product Height Anti-theft Lock Using PCoIP What is a PC over IP?Before Connecting Connection to Use PCoIPPre-connection Checkpoints Connecting to a Video device Connection Using the D-SUB Cable Analogue TypeConnection Using the DVI Cable Connection Using the HDMI-DVICable Connecting to a LAN Connecting a USB DevicesConnecting to Headphones or Speakers Connecting MICConnection Using a Serial Cable Connection Using a Serial CableRemote Control RS232C Gnd Connecting method Connecting to a Secondary Monitor Connecting the Power Connect to host PC using LAN cable PCoIP On Screen Display OSDConnect Screen Connect ButtonOSD Options Menu Configuration Window IPv6 Session Display Label Language ResetEnable Dhcp Network TabEthernet Mode IP AddressSubnet Mask GatewayEnable IPv6 Enable DHCPv6IPv6 Tab Link Local AddressEnable Slaac Label TabSecondary DNS Manual AddressEnable Discovery Discovery TabPCoIP Device Name PCoIP Device DescriptionSession Tab Connection TypeDNS Name or IP Address AdvancedLanguage Tab Keyboard LayoutScreen-Saver Timeout OSD TabDisplay Tab 13 Display Configuration Enable display overrideReset Tab Reset ParametersDiagnostics Window Event Log TabSession Statistics Tab PCoIP Processor Tab 17PCoIP ProcessorPing Tab Information Window † Bootloader Version † Bootloader Build ID† Bootloader Build Date † Firmware Build DateUser Settings Window VMware View TabReject the unverifiable connection Mouse Tab Mouse SpeedKeyboard Repeat Delay Keyboard TabImage Image Quality PreferenceDisplay Topology Display LayoutResolution AlignmentPrimary PositionEnable right click on hold Right click delayTouch Screen Touch screen calibrationPassword Window 26Change Password Old Password27Authorized Password Reset Troubleshooting Guide Check the followingSpecifications GeneralPower consumption Appendix Contact Samsung World WideEurope Denmark Asia Pacific India Africa Responsibility for the Pay Service Cost to Customers Product damage caused by customers faultNot a product defect OthersCorrect Disposal Correct disposal of batteries in this productIndex
Related manuals
Manual 70 pages 14.52 Kb Manual 75 pages 41.59 Kb Manual 2 pages 49.42 Kb Manual 72 pages 31.98 Kb Manual 72 pages 33.12 Kb Manual 74 pages 42.4 Kb Manual 70 pages 14.18 Kb Manual 71 pages 49.18 Kb Manual 70 pages 13.03 Kb

LF-NBNHNN/EN specifications

The Samsung LF-NBNHNN/EN is a standout model in the realm of smart home technology, combining style, functionality, and advanced features. As part of Samsung’s broad range of innovative appliances, this particular model has gained attention for its sleek design and robust capabilities.

One of the most noteworthy features of the LF-NBNHNN/EN is its integration with Samsung's SmartThings ecosystem. This connectivity allows users to control the device seamlessly through their smartphones or tablets, providing convenience and real-time monitoring. With SmartThings, users can also connect multiple devices, creating an efficient smart home environment that can be controlled from virtually anywhere.

This model offers advanced energy-saving technologies that not only contribute to sustainability but also help reduce operating costs. The LF-NBNHNN/EN employs intelligent energy management systems that adjust power consumption based on usage patterns. This means consumers can enjoy modern technology while being mindful of their energy footprint.

The LF-NBNHNN/EN boasts high-performance specifications that cater to various user needs. Whether it is for everyday use or for hosting gatherings, this model delivers excellent performance driven by its powerful motor and advanced cooling technologies. The efficient airflow system ensures that every corner is effectively cooled, maintaining optimal temperatures even on the hottest days.

Another critical aspect of this appliance is its user-friendly interface. Samsung has prioritized usability, making sure that even those less familiar with technology can operate the LF-NBNHNN/EN with ease. The intuitive touchscreen control panel features clear icons and responsive feedback, enhancing the user experience.

Moreover, safety features are a significant focus for this model. It includes child lock settings and automatic shut-off systems that ensure the appliance operates safely and efficiently.

In conclusion, the Samsung LF-NBNHNN/EN is a remarkable blend of advanced technology, energy efficiency, and user-centered design. Its capabilities in connectivity, performance, and safety make it a valuable addition to any modern home, catering to the demands of today’s tech-savvy consumers.