Samsung AQV12FCX, AQV12NSBX, AQV09NSBX Temperature and Humidity Ranges, Operating Recommendations

Page 25

Temperature and Humidity Ranges

If you check the following tables, you can use your air conditioner more efficiently.

If the air conditioner is used at... Then...

Heating capacity

 

The air conditioner may stop operating for the reason of protection.

 

 

 

 

 

 

Low temperatures

 

Water may leak and some malfunction may occur if the heat exchanger freezes.

 

 

 

 

 

 

Protection mechanism

Water may condense and drip from the surface of the indoor unit if you don’t use

the air conditioner for an extended period of time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Temperature

 

 

Operation

 

09/12FC

09/12NSB

Indoor Temperature

Indoor Humidity

 

 

09/12NSA

18/24

 

 

Heating

-10°C to 24°C approx.

-15°C to 24°C approx.

27°C or less

-

Cooling

10°C to 43°C approx.

-10°C to 43°C approx.

16°C to 32°C approx.

80% or less

Dehumidifying

10°C to 43°C approx.

-10°C to 43°C approx.

16°C to 32°C approx.

-

 

 

 

 

 

 

If the outdoor temperature is as low as 0°C, the heating capacity drops up to 70~80% depending on the operating condition.

If you use the air conditioner in temperatures over 32°C (indoor temperature), the cooling capacity may drop.

Operating Recommendations

Here are a few recommendations that you should follow when using your air conditioner.

TopicRecommendation

Heating performances

The heat pump function of the air conditioner absorbs heat from outside air and brings it

 

indoors. As the temperature of the outside air drops, the heating performance of air

 

conditioner will decrease. If you find that the room is not warm enough, using an additional

 

heating appliance is recommended.

 

 

Warm air circulation

The air conditioner circulates warm air to heat your room. It will take some time to warm the

 

air in your room entirely after the air conditioner turns on. Therefore, turn the air conditioner on

 

in advance.

 

 

Frost

When outdoor temperature is low but humidity is high, frost may form on the outdoor unit at

 

Heat mode.

 

The heating operation stops.

 

The defrost mode will be triggered automatically for 3 to 14 minutes.

 

No intervention is required ; after about 7 minutes, the air conditioner operates again normally.

 

 

High indoor and

If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT

outdoor temperatures

mode, the outdoor unit’s fan and compressor may stop at times. This is normal;simply wait until

 

the air conditioner switches on again.

 

 

Power failure

If a power failure occurs while the air conditioner is operating, the unit will be switched off.

 

When the power returns, the air conditioner starts up again automatically.

 

 

Protection mechanism

When the air conditioner is started immediately after being plugged in or stopped, the normal

 

operation starts up after 3 minutes for the reason of protection.

 

 

Cooling operation

The indoor unit may not get the selected fan speed such as Medium and Low under cooling

 

operation at very low outdoor temperatures for the protection of the indoor unit from ice

 

or frost.

 

During Low fan speed operation, cooling performance will be reduced. If the room does not be

 

cooled down when using Low fan speed operation, please adjust the indoor unit’s fan speed.

 

 

Silence Mode

When you operate Silence Mode in cooling and heating, fan speed will decrease to make noise

 

quieter.

 

As a result, the performance of the unit may be reduced.

E-26

FORTE_Inv_IB_E.indd 26

2007-10-18 15:28:52

Image 25 Contents
Contents Safety Precautions During Operation Install the outdoor unit so as Air conditioner for a long time to save energy  Do not touch the pipes connected to the air conditioner Indoor Unit Name of Each PartOutdoor Unit FAN Remote Control-Buttons and DisplayInserting the Remote Control Batteries Getting Started Result Selecting Auto ModeSelecting Cool Mode Selecting Heat Mode Selecting Dry Mode Selecting Fan Mode Selecting Good Sleep Mode Temperature changes in mode Selecting the Turbo Function Adjusting the Airflow Direction Horizontally Adjusting the Airflow Direction VerticallyTo Cancel the On Timer Setting the On TimerTo Cancel the Off Timer Setting the Off TimerRoom Temperature Operating Mode Operating Your Air Conditioner Without the Remote ControlCleaning Deodorizing and Bio filter Option Cleaning Your Air ConditionerOperating Recommendations Temperature and Humidity RangesProblem Explanation/Solution Solving Common ProblemsContact Samsung World Wide Cooling and Heating USER’S Manual