Samsung AQV12YWAX, AQV12KBAN Purging the connected pipes, Connect a drain hose to the drain plug

Page 36

Installing and connecting the drain hose of the outdoor unit

While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following.

1. Insert the drain plug into the drain hole on the underside of the outdoor unit.

• To avoid drain plug from contacting the ground, secure gap between the

 

Drain plug

ground and the bottom surface of the outdoor unit.

Drain hole

 

 

 

 

Bottom surface of outdoor unit

2. Connect a drain hose to the drain plug.

Drain hole

Drain plug

 

 

Drain hose

 

 

 

 

 

3. Ensure that condensation draining is adequate.

 

 

Snow-proof hood

 

 

 

 

 

 

 

 

 

 

 

 

• In areas with heavy snow fall, piled snow could block the air intake.

To avoid this incident, install a frame that is higher than estimated snow

Estimated

fall. In addition, install a snow-proof hood to avoid snow from piling on the

snow fall Frame

outdoor unit.

 

Ground

Purging the connected pipes

If using a multi system, refer to the manual supplied with the outdoor unit.

The outdoor unit is loaded with sufficient R410A refrigerant. Do not vent R410A into atmosphere: it is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 1975.

You should purge the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause reduction of cooling capacity and malfunction. Refrigerant for air purging is not charged in the outdoor unit. Use Vacuum Pump as seen in the picture.

• When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first

before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle

abnormally high. It may cause explosion and injury.

1.Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut.

2.Tighten the flare nut first with your hands, and then with a torque wrench, applying the following torque.

• Excessive torque can be cause of gas leakage.

• Make the electrical connection and leave the system into“stand by mode”. Do not turn on the system!

This is necessary for better vacuum operation (full OPEN position of Electronic Expansion Valve - EEV -).

Outdoor unit

Indoor unit

 

Gas pipe side

 

Liquid pipe side

Outer Diameter

Torque (kgf•cm)

ø6.35 mm

140~170

ø9.52 mm

250~280

ø12.70 mm

380~420

ø15.88 mm

440~480

ø19.05 mm

990~1210

ø22.23 mm

990~1210

36

AQV09K&Y@@_Jungfrau_IBIM_E_32437A.indd 36

2011-1-17 17:07:22

Image 36
Contents AQV09K&Y@@JungfrauIBIME32437A.indd 2011-1-17 Contents Safety precautions Important safety symbols and precautionsFollow directions Wall socketFor Using For Cleaning Checking before use Operation rangesModel RJ Checking the name of the parts Main partsDisplay Checking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Button to adjust the temperature PressAdjusting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowWhen the air conditioner is on and in cool/heat mode Press the button on the remote controllerPress the Set/Cancel button to active it ModeSetting the Current time Setting the On/Off timerAdditional options available in On timer mode Follow the same process for setting on timer and off timerUsing the Smart Saver function Using the SPi functionUsing the Auto Clean function Using the dlight Cool functionWhen the air conditioner is turned on Cancel Press the Auto clean button once againUsingAA the Quiet function You can reduce the noise generated from an indoor unitCleaning the indoor unit Cleaning the outdoor unit heat exchangerOpening the panel Heat exchangerCleaning the air conditioner Cleaning the Full HD filterRemoving the Full HD filter Dry the Full HD filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Error is indicated All blinkNoise is generated Outdoor unitGeneral information Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor UnitModel When installing 1 outdoor unit When installing more than 1 outdoor unitSpace Requirements for Outdoor Unit Side viewAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Unit mmFixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Fix the indoor unit If you fix the indoor unit on a wallExtend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberSmooth the cut edges Cut off the remaining foam insulationPurging the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flarePipe 50 Pa. The joint must be accessible and serviceable Correct InclinedCracked Outer DiameterDrain hose installation Purging the connected pipes Connect a drain hose to the drain plugEnsure that condensation draining is adequate Gas service port as seen in the picture Adding RefrigerantIf you use a pipe longer than 5m If you use a pipe shorter than 5mPlease fill in with indelible ink  the factory refrigerant charge of the product1975 Performing the gas leak tests To check for gas leaks on the outdoor unitTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesThen place the indoor unit on the installation plate Fixing the indoor unit in placeFixing the outdoor unit in place 612Final Check and Trial Operation How to connect your extended power cables Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with Insulation tape to finishSub PCB installationoptional Only for multi system Wried remote controller, central remote controller etc42 27 7267864, € 0.07/min70 70 19 +381Air Conditioner
Related manuals
Manual 43 pages 36.93 Kb Manual 43 pages 57.93 Kb Manual 43 pages 16.42 Kb Manual 45 pages 57.87 Kb Manual 43 pages 7.81 Kb Manual 43 pages 10.58 Kb Manual 45 pages 17.94 Kb Manual 43 pages 52.7 Kb Manual 23 pages 29.57 Kb Manual 43 pages 11.43 Kb Manual 43 pages 54.66 Kb Manual 45 pages 44.27 Kb Manual 52 pages 58.4 Kb Manual 52 pages 46.07 Kb Manual 1 pages 8.03 Kb Manual 23 pages 40.87 Kb Manual 25 pages 1.01 Kb Manual 23 pages 9.1 Kb Manual 52 pages 18.48 Kb Manual 23 pages 42.75 Kb Manual 23 pages 46.31 Kb Manual 16 pages 35.53 Kb Manual 23 pages 46.82 Kb Manual 42 pages 45.49 Kb Manual 23 pages 57.56 Kb Manual 41 pages 25.73 Kb Manual 41 pages 25.56 Kb Manual 43 pages 9.83 Kb Manual 21 pages 49.66 Kb Manual 21 pages 36.79 Kb Manual 16 pages 16.35 Kb Manual 41 pages 6.72 Kb Manual 41 pages 27.43 Kb Manual 41 pages 20.41 Kb Manual 21 pages 39.04 Kb Manual 21 pages 44.89 Kb Manual 21 pages 55.58 Kb Manual 45 pages 56.11 Kb

AQV18KBAN, AQV09YWAN, AQV09KBAN, AQV18YWAX, AQV09KBAX specifications

Samsung has long been a major player in the electronics market, and its air conditioning units are no exception. Models like AQV12KBAX, AQV12YWAN, AQV18YWAN, AQV09YWAX, and AQV12YWAX showcase the company’s commitment to innovation and user comfort, providing advanced features and superior performance.

The AQV12KBAX is known for its efficient cooling capabilities, leveraging the inverter technology which adjusts the compressor speed based on room temperature, thereby reducing energy consumption and maintaining a consistent temperature. This model also features a quiet operation mode, ensuring that it does not disturb your peace while providing optimal cooling.

Moving to the AQV12YWAN and AQV18YWAN, these models incorporate Samsung’s WindFree cooling technology. This unique feature allows the air conditioner to distribute cool air without the discomfort of direct cold drafts, resulting in a more comfortable indoor environment. The energy-efficient design means that these units can cool larger spaces while utilizing less power, making them an excellent choice for households looking to reduce their energy bills without sacrificing comfort.

The AQV09YWAX and AQV12YWAX models are especially noteworthy for their smart features. They can be integrated with smart home systems, allowing users to control their air conditioning units remotely via smartphone applications. This not only provides convenience but also enables users to monitor energy consumption in real-time, optimizing usage based on their schedules.

All these models are equipped with advanced air purification technology, ensuring that the air circulated is not only cool but also clean. This feature is particularly valuable for those with allergies or respiratory issues, as it helps to filter out dust, pollen, and other airborne pollutants.

In terms of design, Samsung’s air conditioning units are sleek and modern, making them a stylish addition to any room. With their compact size and elegant aesthetics, they blend seamlessly into any interior while providing powerful performance.

In conclusion, Samsung's AQV12KBAX, AQV12YWAN, AQV18YWAN, AQV09YWAX, and AQV12YWAX air conditioning models represent the pinnacle of modern HVAC technology. Their combination of energy efficiency, user-friendly features, and advanced cooling capabilities make them an excellent choice for those seeking reliable climate control solutions. Whether for a small room or a larger living area, Samsung’s air conditioning units deliver comfort, cleanliness, and convenience.