Samsung AQV10UWEX manual Connecting the assembly cable, Cable specification, Connecting the cable

Page 28

Fixing the installation plate

2. Fix the indoor unit.

If you fix the indoor unit on a wall

(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.

• If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20mm.

Plastic

Anchor

<20mm

Wall

If you fix the indoor unit on a window frame

(1)Determine the positions of the wooden uprights to be attached to the window frame.

(2)Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

(3)Attach the installation plate to the wooden upright using tapping screws.

If you fix the indoor unit on a gypsum board

(1)Use stud finder to find out locations of the studs.

(2)Fix the plate hanger on two studs.

Search for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger.

Fix the installation plate without inclining to one side.

Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not

strong enough to withstand the product weight, the unit could fall and cause injury.

Connecting the assembly cable

Cable specification

Model

Power cable

Interconnection cable

Type GL

 

 

 

 

 

 

 

 

 

 

09/10/12

-

4G, 1.5mm² H07RN-F

20A

 

 

 

 

 

 

18/24

3G, 2.5mm² H07RN-F

3G, 1.5mm² H07RN-F

25A

2G, 0.75mm² H05RN-F

 

 

 

 

 

• Connect the power cable to the auxiliary circuit breaker. If every pole fails to connect to the power supply, it must be incorporated in a wire with a contact opening of ≥3mm.

Connecting the cable

When you install the unit, make first refrigerant connections and then electrical connections. Connect the air conditioner to grounding system before performing the electrical connection. If unit is uninstalled, first disconnect electrical cables, then refrigerant connections.

If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable.

The maximum length of the cable is 15(09/10/12)/20(18/24) meters.

1.Extend the assembly cable if necessary.

Do not connect two or more different cables to extend the length. It may cause fire.

28

Vivaldi MAX_AQV09&12U@@ IB&IM_32450A_E.indd 28

2011-3-7 15:12:16

Image 28
Contents Vivaldi MAXAQV09&12U@@ IB&IM32450AE.indd 2011-3-5 Contents Safety precautions Important safety symbols and precautionsFollow directions Wall socketFor Using For Cleaning Checking before use Operation rangesPower button Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Button to adjust the temperature PressAdjusting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowWhen the air conditioner is on and in cool/heat mode Press the button on the remote controllerMode Press the Time Up or Time Down button to set the timeSetting the On/Off timer Press the On Timer/Off Timer buttonCancel Press the Cancel button Additional options available in On timer modeUsing the Smart Saver function From the moment you have set the timerIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsing the Quiet function Using the Auto Clean functionWhen the air conditioner is turned on You can reduce the noise generated from an indoor unitCleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelCleaning the air filter Removing the Air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Flow movement changes. It is normal Outdoor unit Heat exchanger during Heat mode in winterConnection General information Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyOutdoor Unit Where sulfide gas existsModel When installing more than 1 outdoor unit When the air outlet is towards the wall Figure Description Top view Side viewAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Each wire is labeled with the corresponding terminal number 09/10/1218/24Smooth the cut edges Cut off the remaining foam insulationPurging the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flarePipe 50 Pa. The joint must be accessible and serviceable Correct InclinedCracked Outer DiameterDrain hose installation Connect a drain hose to the drain plug Purging the connected pipesEnsure that condensation draining is adequate Adding Refrigerant  the factory refrigerant charge of the product Please fill in with indelible ink1975 Performing the gas leak tests To check for gas leaks on the outdoor unitTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesOutdoor unit installed on the wall by rack Then place the indoor unit on the installation plateFixing the indoor unit in place Fixing the outdoor unit in placeFinal Check and Trial Operation How to connect your extended power cables Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with Insulation tape to finishEnglish 42 27 Samsung 7267864, € 0.07/min02-201-24-18 05 133Air Conditioner
Related manuals
Manual 39 pages 38.72 Kb Manual 41 pages 5.78 Kb

AQV10UWEX, AQV12UGEX, AQV09UGEX, AQV10UWEN, AQV12UGEN specifications

Samsung has consistently been at the forefront of innovation in the air conditioning market, and their latest models, the AQV09UGEN, AQV12UGEN, AQV09UGEX, and AQV12UGEX, exemplify this commitment to quality and efficiency. These models are designed to meet the demanding needs of modern households and commercial spaces while ensuring optimal climate control.

One of the standout features of these air conditioners is their inverter technology. The inverter compressor allows for variable speed operation, which enables the unit to adjust its cooling capacity according to the ambient temperature and the specific cooling load required. This not only ensures rapid cooling but also enhances energy efficiency, reducing electricity costs while maintaining a consistently comfortable indoor environment.

The AQV series is also equipped with advanced filtration systems that improve indoor air quality. With features like a HEPA filter, these models capture fine dust, allergens, and other pollutants, ensuring that the air circulated within the room is clean and healthy. This makes these units ideal for families, particularly those with children or individuals with respiratory issues.

Another important characteristic of the AQV09UGEN, AQV12UGEN, AQV09UGEX, and AQV12UGEX models is their quiet operation. Noise levels have been minimized through thoughtful engineering, allowing users to enjoy a peaceful atmosphere while the units function effectively in the background. This feature is particularly beneficial for bedrooms, offices, and other quiet areas where noise could be disruptive.

Additionally, these air conditioners come with smart technology integration. With Wi-Fi connectivity, users can control their air conditioning units remotely through a smartphone app. This not only offers convenience but also the ability to optimize energy usage by programming cooling times according to personal schedules.

The sleek design of the AQV series also deserves mention. With clean lines and a modern aesthetic, these air conditioners can seamlessly blend into a variety of interior décors, making them an attractive addition to any space. Furthermore, they are designed for easy installation and maintenance, which is a significant advantage for both consumers and technicians.

In summary, the Samsung AQV09UGEN, AQV12UGEN, AQV09UGEX, and AQV12UGEX air conditioners offer a compelling combination of inverter technology, advanced filtration, quiet operation, smart features, and stylish design. They represent an effective solution for individuals and businesses looking to enhance their indoor comfort while prioritizing energy efficiency and air quality. With these models, Samsung continues to set a high standard in the air conditioning industry, ensuring customer satisfaction and peace of mind.