Samsung AQV12UGEN, AQV09UGEN, AQV12UGEX, AQV09UGEX Correct Inclined, Cracked, Outer Diameter, Ditch

Page 32

Cutting or extending the pipe

5. Check if you flared the pipe correctly (see examples of incorrectly flared pipes below).

Correct

Inclined

Damaged

Cracked

Uneven

 

 

Surface

 

Thickness

6.Align the pipes to connect them easily. Tighten the flare nuts first with your hands, and then with a torque wrench, applying the following torque:

Flare nut

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor outlet

 

pipe

 

 

 

 

 

Connecting pipe

Outer Diameter

Torque (kgf•cm)

ø6.35 mm

140~170

ø9.52 mm

250~280

ø12.70 mm

380~420

ø15.88 mm

440~480

ø19.05 mm

990~1210

ø22.23 mm

990~1210

• Excessive torque can be cause of gas leakage. In case brazing the pipe, the nitrogen gas must be blown into the

pipe (50 Pa). The joint must be accessible and serviceable.

7. For further details on how to connect to the outdoor unit and purge the air, refer to page 34~36.

• Tighten the flare nut with torque wrench according to specified method.

If the flare nut is over-tightened, the flare may break and cause refrigerant gas leakage.

Installing and connecting the drain hose of the indoor unit

When installing the drain hose for the indoor unit, check if condensation draining is adequate. When passing the drain hose through the 65-mm hole drilled in the wall, check the followings:

Wall

Indoor unit

Drain hose

The drain hose must not be bent.

The drain hose must NOT slant upwards.

5cm less

Keep a clearance of at least 5cm between the end of the drain hose and the ground.

The end of the drain hose must NOT be placed under water.

Ditch

Do not place the end of the drain hose in a hollow.

32

Vivaldi MAX_AQV09&12U@@ IB&IM_32450A_E.indd 32

2011-3-5 15:26:34

Image 32
Contents Vivaldi MAXAQV09&12U@@ IB&IM32450AE.indd 2011-3-5 Contents Safety precautions Important safety symbols and precautionsFollow directions Wall socketFor Using For Cleaning Checking before use Operation rangesPower button Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Button to adjust the temperature PressAdjusting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowWhen the air conditioner is on and in cool/heat mode Press the button on the remote controllerMode Press the Time Up or Time Down button to set the timeSetting the On/Off timer Press the On Timer/Off Timer buttonCancel Press the Cancel button Additional options available in On timer modeUsing the Smart Saver function From the moment you have set the timerIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsing the Quiet function Using the Auto Clean functionWhen the air conditioner is turned on You can reduce the noise generated from an indoor unitCleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelCleaning the air filter Removing the Air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Connection Outdoor unit Heat exchanger during Heat mode in winterFlow movement changes. It is normal General information Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyModel Where sulfide gas existsOutdoor Unit When installing more than 1 outdoor unit When the air outlet is towards the wall Figure Description Top view Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the cable Connecting the assembly cableCable specification Each wire is labeled with the corresponding terminal number 09/10/1218/24Smooth the cut edges Cut off the remaining foam insulationPurging the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flarePipe 50 Pa. The joint must be accessible and serviceable Correct InclinedCracked Outer DiameterDrain hose installation Ensure that condensation draining is adequate Purging the connected pipesConnect a drain hose to the drain plug Adding Refrigerant 1975 Please fill in with indelible ink the factory refrigerant charge of the product Performing the gas leak tests To check for gas leaks on the outdoor unitTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesOutdoor unit installed on the wall by rack Then place the indoor unit on the installation plateFixing the indoor unit in place Fixing the outdoor unit in placeFinal Check and Trial Operation How to connect your extended power cables Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with Insulation tape to finishEnglish 42 27 Samsung 7267864, € 0.07/min02-201-24-18 05 133Air Conditioner
Related manuals
Manual 39 pages 38.72 Kb Manual 41 pages 5.78 Kb

AQV10UWEX, AQV12UGEX, AQV09UGEX, AQV10UWEN, AQV12UGEN specifications

Samsung has consistently been at the forefront of innovation in the air conditioning market, and their latest models, the AQV09UGEN, AQV12UGEN, AQV09UGEX, and AQV12UGEX, exemplify this commitment to quality and efficiency. These models are designed to meet the demanding needs of modern households and commercial spaces while ensuring optimal climate control.

One of the standout features of these air conditioners is their inverter technology. The inverter compressor allows for variable speed operation, which enables the unit to adjust its cooling capacity according to the ambient temperature and the specific cooling load required. This not only ensures rapid cooling but also enhances energy efficiency, reducing electricity costs while maintaining a consistently comfortable indoor environment.

The AQV series is also equipped with advanced filtration systems that improve indoor air quality. With features like a HEPA filter, these models capture fine dust, allergens, and other pollutants, ensuring that the air circulated within the room is clean and healthy. This makes these units ideal for families, particularly those with children or individuals with respiratory issues.

Another important characteristic of the AQV09UGEN, AQV12UGEN, AQV09UGEX, and AQV12UGEX models is their quiet operation. Noise levels have been minimized through thoughtful engineering, allowing users to enjoy a peaceful atmosphere while the units function effectively in the background. This feature is particularly beneficial for bedrooms, offices, and other quiet areas where noise could be disruptive.

Additionally, these air conditioners come with smart technology integration. With Wi-Fi connectivity, users can control their air conditioning units remotely through a smartphone app. This not only offers convenience but also the ability to optimize energy usage by programming cooling times according to personal schedules.

The sleek design of the AQV series also deserves mention. With clean lines and a modern aesthetic, these air conditioners can seamlessly blend into a variety of interior décors, making them an attractive addition to any space. Furthermore, they are designed for easy installation and maintenance, which is a significant advantage for both consumers and technicians.

In summary, the Samsung AQV09UGEN, AQV12UGEN, AQV09UGEX, and AQV12UGEX air conditioners offer a compelling combination of inverter technology, advanced filtration, quiet operation, smart features, and stylish design. They represent an effective solution for individuals and businesses looking to enhance their indoor comfort while prioritizing energy efficiency and air quality. With these models, Samsung continues to set a high standard in the air conditioning industry, ensuring customer satisfaction and peace of mind.