Samsung AQV09UGEX Safety precautions, Important safety symbols and precautions, Follow directions

Page 3

USING PARTS

Safety precautions

Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance.

Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com.

Important safety symbols and precautions:

WARNING Hazards or unsafe practices that may result in severe personal injury or death.

CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage.

Follow directions.

 

Unplug the power plug from the

 

wall socket.

 

 

Do NOT attempt.

 

Do NOT disassemble.

 

 

 

Make sure the machine is grounded to prevent electric shock.

FOR INSTALLATION

WARNING

Plug the power cord into a wall socket with the power specifications of the product or higher and use the socket for this appliance only. In addition, do not use an extension cord.

Sharing a wall socket with other appliances using a power strip or extending the power cord may result in electric shock or fire.

Do not use an electric transformer. It may result in electric shock or fire.

If the voltage/frequency/rated current condition is different, it may cause fire.

The installation of this appliance must be performed by a qualified technician or service company.

Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury.

Install a switch and circuit breaker dedicated to the air conditioner.

Failing to do so may result in electric shock or fire.

Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.

Failing to do so may result in electric shock or fire.

Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak.

This may result in electric shock or fire.

Never install the outdoor unit in a location such as on a high external wall where it could fall.

If the outdoor unit falls, it may result in injury, death or property damage.

This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line.

Failure to do so may result in electric shock, fire, an explosion, or other problems with the product.

Never plug the power cord into a socket that is not grounded correctly and make sure that it is in accordance with local and national codes.

FOR INSTALLATION

CAUTION

This appliance should be positioned in such a way that it is accessible to the power plug.

Failing to do so may result in electric shock or fire due to electric leakage.

Install your appliance on a level and hard floor that can support its weight.

Failing to do so may result in abnormal vibrations, noise, or problems with the product.

Install the draining hose properly so that water is drained correctly.

Failing to do so may result in water overflowing and property damage.

When installing the outdoor unit, make sure to connect the draining hose so that draining is performed correctly.

The water generated during the heating operation by the outdoor unit may overflow and result in property damage. In particular, in winter, if a block of ice falls, it may result in injury, death or property damage.

ENGLISH

3

Vivaldi MAX_AQV09&12U@@ IB&IM_32450A_E.indd 3

2011-3-5 15:25:39

Image 3
Contents Vivaldi MAXAQV09&12U@@ IB&IM32450AE.indd 2011-3-5 Contents Wall socket Safety precautionsImportant safety symbols and precautions Follow directionsFor Using For Cleaning Operation ranges Checking before useDisplay Power buttonChecking the name of the parts Main partsRemote controller buttons Checking the remote controllerInserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Press Button to adjust the temperatureVertical air flow Adjusting the air flow directionUsing the Turbo function Press the Air swing button on the remote controllerPress the Time Up or Time Down button to set the time When the air conditioner is on and in cool/heat modePress the button on the remote controller ModeAdditional options available in On timer mode Setting the On/Off timerPress the On Timer/Off Timer button Cancel Press the Cancel buttonTurn off automatically Using the Smart Saver functionFrom the moment you have set the timer If the air conditioner is on If the air conditioner is offYou can reduce the noise generated from an indoor unit Using the Quiet functionUsing the Auto Clean function When the air conditioner is turned onOpening the panel Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerDry the Air filter in a ventilated area Cleaning the air filterRemoving the Air filter Open the panel and put the Air filter outPeriodical checks Maintaining the air conditionerTroubleshooting Outdoor unit Heat exchanger during Heat mode in winter Flow movement changes. It is normalConnection General information  a place where the air filter can be replaced easily Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerWhere sulfide gas exists Outdoor UnitModel Top view Side view When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the assembly cable Cable specificationConnecting the cable 09/10/1218/24 Each wire is labeled with the corresponding terminal numberCut off the remaining foam insulation Smooth the cut edgesPut a flare nut slightly into the pipe and modify the flare Purging the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeOuter Diameter Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined CrackedDrain hose installation Purging the connected pipes Connect a drain hose to the drain plugEnsure that condensation draining is adequate Adding Refrigerant Please fill in with indelible ink  the factory refrigerant charge of the product1975 Leak test with nitrogen before opening valves Performing the gas leak testsTo check for gas leaks on the outdoor unit To check for gas leaks on the indoor unitFixing the outdoor unit in place Outdoor unit installed on the wall by rackThen place the indoor unit on the installation plate Fixing the indoor unit in placeFinal Check and Trial Operation Insulation tape to finish How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish 05 133 42 27Samsung 7267864, € 0.07/min 02-201-24-18Air Conditioner
Related manuals
Manual 39 pages 38.72 Kb Manual 41 pages 5.78 Kb

AQV10UWEX, AQV12UGEX, AQV09UGEX, AQV10UWEN, AQV12UGEN specifications

Samsung has consistently been at the forefront of innovation in the air conditioning market, and their latest models, the AQV09UGEN, AQV12UGEN, AQV09UGEX, and AQV12UGEX, exemplify this commitment to quality and efficiency. These models are designed to meet the demanding needs of modern households and commercial spaces while ensuring optimal climate control.

One of the standout features of these air conditioners is their inverter technology. The inverter compressor allows for variable speed operation, which enables the unit to adjust its cooling capacity according to the ambient temperature and the specific cooling load required. This not only ensures rapid cooling but also enhances energy efficiency, reducing electricity costs while maintaining a consistently comfortable indoor environment.

The AQV series is also equipped with advanced filtration systems that improve indoor air quality. With features like a HEPA filter, these models capture fine dust, allergens, and other pollutants, ensuring that the air circulated within the room is clean and healthy. This makes these units ideal for families, particularly those with children or individuals with respiratory issues.

Another important characteristic of the AQV09UGEN, AQV12UGEN, AQV09UGEX, and AQV12UGEX models is their quiet operation. Noise levels have been minimized through thoughtful engineering, allowing users to enjoy a peaceful atmosphere while the units function effectively in the background. This feature is particularly beneficial for bedrooms, offices, and other quiet areas where noise could be disruptive.

Additionally, these air conditioners come with smart technology integration. With Wi-Fi connectivity, users can control their air conditioning units remotely through a smartphone app. This not only offers convenience but also the ability to optimize energy usage by programming cooling times according to personal schedules.

The sleek design of the AQV series also deserves mention. With clean lines and a modern aesthetic, these air conditioners can seamlessly blend into a variety of interior décors, making them an attractive addition to any space. Furthermore, they are designed for easy installation and maintenance, which is a significant advantage for both consumers and technicians.

In summary, the Samsung AQV09UGEN, AQV12UGEN, AQV09UGEX, and AQV12UGEX air conditioners offer a compelling combination of inverter technology, advanced filtration, quiet operation, smart features, and stylish design. They represent an effective solution for individuals and businesses looking to enhance their indoor comfort while prioritizing energy efficiency and air quality. With these models, Samsung continues to set a high standard in the air conditioning industry, ensuring customer satisfaction and peace of mind.