Performance
Candlepower Curve
| |||
|
| ||
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
| ||
|
| ||
|
|
| |
|
|
| |
|
| ||
|
|
| |
|
|
| |
|
| ||
|
|
| |
| |||
|
|
Report No: 2101640
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 82.2%
Up: 79.4% Down: 20.6%
Candlepower Summary
ZONE |
| CANDLEPOWER |
| ||
DEG. | 0 | 22.5 | 45 | 67.5 | 90 |
180 | 1598 | 1598 | 1598 | 1598 | 1598 |
175 | 1590 | 1592 | 1596 | 1601 | 1602 |
165 | 1536 | 1546 | 1557 | 1567 | 1573 |
155 | 1434 | 1449 | 1474 | 1493 | 1505 |
145 | 1286 | 1306 | 1365 | 1439 | 1461 |
135 | 1092 | 1123 | 1249 | 1357 | 1397 |
125 | 865 | 922 | 1111 | 1274 | 1338 |
115 | 613 | 712 | 988 | 1191 | 1254 |
105 | 339 | 524 | 804 | 847 | 904 |
95 | 84 | 222 | 379 | 363 | 427 |
90 | 5 | 34 | 48 | 61 | 59 |
85 | 15 | 33 | 56 | 63 | 68 |
75 | 55 | 54 | 77 | 91 | 99 |
65 | 113 | 131 | 82 | 96 | 103 |
55 | 259 | 254 | 190 | 101 | 99 |
45 | 431 | 338 | 355 | 266 | 254 |
35 | 609 | 510 | 469 | 445 | 447 |
25 | 770 | 726 | 593 | 533 | 548 |
15 | 901 | 915 | 857 | 745 | 730 |
5 | 979 | 981 | 998 | 999 | 1007 |
0 | 987 | 987 | 987 | 987 | 987 |
2 Light T5 HO Direct/Indirect
Coefficients of Utilization
|
| % EFFECTIVE CEILING CAVITY REFLECTANCE |
| |||||||
|
| 80 |
|
| 70 |
|
|
| 50 |
|
|
|
|
| % WALL REFLECTANCE |
|
|
| |||
| 50 | 30 | 10 | 50 | 30 | 10 |
| 50 | 30 | 10 |
0 | 82 | 82 | 82 | 73 | 73 | 73 |
| 55 | 55 | 55 |
1 | 72 | 69 | 66 | 63 | 61 | 59 |
| 48 | 46 | 45 |
2 | 63 | 58 | 54 | 56 | 52 | 48 |
| 42 | 40 | 37 |
3 | 55 | 50 | 45 | 49 | 44 | 41 |
| 37 | 34 | 32 |
4 | 49 | 43 | 38 | 44 | 38 | 34 |
| 33 | 30 | 27 |
5 | 44 | 37 | 33 | 39 | 34 | 30 |
| 30 | 26 | 23 |
6 | 39 | 33 | 28 | 35 | 30 | 26 |
| 27 | 23 | 20 |
7 | 35 | 29 | 25 | 31 | 26 | 22 |
| 24 | 21 | 18 |
8 | 32 | 26 | 22 | 28 | 23 | 20 |
| 22 | 18 | 16 |
9 | 29 | 23 | 19 | 26 | 21 | 18 |
| 20 | 17 | 14 |
10 | 26 | 21 | 17 | 24 | 19 | 16 |
| 19 | 15 | 13 |
Zonal Lumen Summary |
| ||
ZONE | LUMENS | %BARE LAMP | %LUMINAIRE |
1573 | 16.9 | 20.6 | |
6073 | 65.3 | 79.4 | |
7646 | 82.2 | 100.0 |
Module Lengths & Mounting Distances
@
@
@
Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).
Run Configuration
Run | 4’ | 8’ | 12’ | Joiner | End Set | Mount | Power | |
Length | Module | Module | Module | Mount* | ||||
|
|
| ||||||
|
|
|
|
|
|
|
| |
4’ run | 1 |
|
|
| 1 | 1 | 1 | |
|
|
|
|
|
|
|
| |
8’ run |
| 1 |
|
| 1 | 1 | 1 | |
|
|
|
|
|
|
|
| |
12’ run |
|
| 1 |
| 1 | 1 | 1 | |
|
|
|
|
|
|
|
| |
16’ run |
| 2 |
| 1 | 1 | 2 | 1 | |
|
|
|
|
|
|
|
| |
20’ run |
| 1 | 1 | 1 | 1 | 2 | 1 | |
|
|
|
|
|
|
|
| |
24’ run |
|
| 2 | 1 | 1 | 2 | 1 | |
|
|
|
|
|
|
|
| |
28’ run |
| 2 | 1 | 2 | 1 | 3 | 1 | |
|
|
|
|
|
|
|
| |
32’ run |
| 1 | 2 | 2 | 1 | 3 | 1 | |
|
|
|
|
|
|
|
|
*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.
System Components & Accessories
End Set
BSLESW = suspended standard white
Joiner |
BSLJS = suspended joiner
Job Information | Type: |
Lightolier a Genlyte Company | www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2005 Genlyte Group LLC • 0205 Rev.1