Configuration Using Web-Manager

Endpoint Configuration

Local Port

Enter the local port number.

 

 

Auto increment local

Select to auto-increment the local port number for new

port number

outgoing connections. The range of auto-incremented port

 

numbers is 50,000 to 59,999 and loops back to the beginning

 

when the maximum range is reached.

 

 

Remote Port

Enter the remote port number.

 

 

Remote Host

Enter the IP address of the remote device.

 

 

Common Options

Telnet Mode

This field is available for configuration only when Active

 

Connection is not set to None. Select Enable to permit Telnet

 

communication to the WiPort unit.

 

 

Terminal Name

This field is available for configuration only when Telnet Mode

 

is set to Enable.

 

Use the terminal name for the Telnet terminal type. Enter only

 

one name. When this option is enabled, the unit also reacts to

 

the EOR (end of record) and binary options, which can be

 

used for applications such as terminal emulation to IBM hosts.

 

 

Connect Response

A single character is transmitted to the serial port when there

 

is a change in connection state. Default setting is None.

 

 

Use Hostlist

If this option is set to True, the device server scrolls through

 

the host list until it connects to a device listed in the host list

 

table. Once it connects, the unit stops trying to connect to any

 

others. If this connection fails, the unit continues to scroll

 

through the table until it is able to connect to another IP in the

 

host list.

 

The host list is disabled for Manual Mode and for Modem

 

Mode. The unit will not accept a data connection from a

 

remote device when the host list option is enabled.

 

For information on configuring the host list, see Host List

 

Configuration on page 4-5.

 

 

LED

Select Blink for the status LEDs to blink upon connection or

 

None for no LED output.

 

 

Disconnect Mode

On Mdm_Ctrl_In Drop

Set to Yes for the network connection to or from the serial port

 

to drop when modem_control_in transitions from a high state

 

to a low state.

 

 

Hard Disconnect

When set to Yes, the TCP connection closes even if the

 

remote site does not acknowledge the disconnect request.

 

 

With EOT

Choose Yes to drop the connection when Ctrl-D or Hex 04 is

 

detected. Both Telnet mode and Disconnect with EOT must

 

be enabled for Disconnect with EOT to function properly. Ctrl

 

D is only detected going from the serial port to the network.

 

 