Configuration Using Web-Manager

Inactivity Timeout

Use this parameter to set an inactivity timeout. The unit drops the connection if there is no activity on the serial line before the set time expires. Enter time in the format mm:ss, where m is the number of minutes and s is the number of seconds. To disable the inactivity timeout, enter 00:00.

Connection Settings - UDP

To configure a channel’s UDP settings:

1.From the main menu, click Connection for either Channel 1 or Channel 2 to display the Connection Settings page for the selected channel.

2.In the available fields, enter the following information:

Connect Protocol

Protocol

Select UDP from the pull down menu.

Figure 4-7. UDP Connection Settings

Datagram Mode

Datagram Type

Configures remote IP or network broadcast address and the

 

remote port. Enter 01 for directed or broadcast UDP.

 

 

Accept Incoming

Select Yes to accept incoming UDP datagrams.

 

 

Endpoint Configuration

Local Port

Enter the local port number.

WiPort™ User Guide

4-11