Configuration Via Serial Mode or Telnet Port

Hostlist

If this option is set to True, the device server scrolls through the host list until it connects to the first available device listed in the host list table. Once it connects, the unit stops further attempts. If this connection fails, the unit continues to scroll through the table until it is able to connect to the next available IP address in the host list.

Hostlist supports a minimum of 1 and a maximum of 12 entries. Each entry contains the IP address and the port number.

The hostlist is disabled for Manual Mode and for Modem Mode. The unit will not accept a data connection from a remote device when the hostlist option is enabled.

 

Figure 5-6. Hostlist Example

 

Baudrate (9600) ?

 

I/F Mode (4C) ?

 

Flow (00) ?

 

Port No (10001) ?

 

ConnectMode (C0) ?25

 

Hostlist :

 

No Entry !

 

Change Hostlist ? (N) Y

Port :

01.

IP address : (000) 172.(000) 19.(000) 0.(000) 1

(0)

?23

Port :

02.

IP address : (000) 172.(000) 19.(000) 0.(000) 2

(0)

?3001

Port :

03.

IP address : (000) 172.(000) 19.(000) 0.(000) 3

(0)

?10001

 

04.

IP address : (000) .(000) .(000) .(000)

 

Hostlist :

01.IP : 172.019.000.001 Port : 00023

02.IP : 172.019.000.002 Port : 03001

03.IP : 172.019.000.003 Port : 10001

Change Hostlist ? (N) N

Hostlist Retrycounter (3) ?

Hostlist Retrytimeout (250) ?

DisConnMode (00) ?

FlushMode (00) ?

DisConnTime (00:00) ?:

SendChar 1 (00) ?

SendChar 2 (00) ?

To enable the hostlist:

1.Enter a Connect Mode of 0x20. The menu shows a list of current entries already defined in the product.

2.To delete, modify, or add an entry, select Yes. If entering an IP address of 0.0.0.0, that entry and all others after it are deleted.

3.After completing the hostlist, repeat the previous step if necessary to edit the hostlist again.