Configuration Using Web-Manager

Pack Control

Enable Packing

Select the checkbox to enable packing on the WiPort.

 

Two firmware-selectable packing algorithms define how and

 

when packets are sent to the network. The standard algorithm

 

is optimized for applications in which the unit is used in a local

 

environment, allowing for very small delays for single

 

characters, while keeping the packet count low. The alternate

 

packing algorithm minimizes the packet count on the network

 

and is especially useful in applications in a routed Wide Area

 

Network (WAN). Adjusting parameters in this mode can

 

economize the network data stream.

 

 

Idle Gap Time

Select the maximum time for inactivity. The default time is 12

 

milliseconds.

 

 

Match 2 Byte Sequence

Use to indicate the end of a series of data to be sent as one

 

group. The sequence must occur sequentially to indicate to

 

the WiPort end of the data collection.

 

 

Match Bytes

Use to indicate the end of a series of data to be sent as one

 

group. Set this value to 00 if specific functions are not

 

needed.

 

 

Send Frame Only

After the detection of the byte sequence, indicates whether to

 

send the data frame or the entire buffer. Select True to send

 

only the data frame.

 

 

Send Trailing Bytes

Select the number of bytes to send after the end-of-sequence

 

characters.

 

 

Flush Input Buffer (Serial to Network)

With Active Connect

Select Yes to clear the input buffer with a connection that is

 

initiated from the device to the network.

 

 

With Passive Connect

Select Yes to clear the input buffer with a connection initiated

 

from the network to the device.

 

 

At Time of Disconnect

Select Yes to clear the input buffer when the network

 

connection to or from the device is disconnected.

 

 

Flush Output Buffer (Network to Serial)

With Active Connect

Select Yes to clear the output buffer with a connection that is

 

initiated from the device to the network.

 

 

With Passive Connect

Select Yes to clear the output buffer with a connection initiated

 

from the network to the device.

 

 

At Time of Disconnect

Select Yes to clear the output buffer when the network

 

connection to or from the device is disconnected.

 

 

Connection Settings - TCP

To configure a channel’s TCP settings:

1.From the main menu, click Connection for either Channel 1 or Channel 2 to display the Connection Settings page for the selected channel.

2.In the available fields, enter the following information:

4-8