Configuration Using DeviceInstaller

Connection Response

A single character is transmitted to the serial port when there is a change in connection state. Default setting is None.

Disconnection

 

Disable Hard Disconnect

The TCP connection closes even if the remote site does not

 

 

acknowledge a disconnect request.

 

 

 

 

Disconnect with

The connection drops when modem_control_in transitions

 

modem_control_in

from a high state to a low state.

 

 

 

 

Disconnect with EOT

The connection is dropped when Ctrl-D or Hex 04 is detected.

 

 

Both Telnet mode and Disconnect with EOT must be enabled

 

 

for Disconnect with EOT to function properly. Ctrl D is only

 

 

detected going from the serial port to the network.

 

 

 

 

Inactivity Timeout

Use this parameter to set an inactivity timeout. The unit drops

 

 

the connection if there is no activity on the serial line before

 

 

the set time expires. Enter time in the format mm:ss, where m

 

 

is the number of minutes and s is the number of seconds. To

 

 

disable the inactivity timeout, enter 00:00.

 

 

 

Connection

 

Connection LED

Select Blink for the status LEDs to blink upon connection or None for no LED output.

Buffer Flushing

Flush Input Buffer

 

At Time of Disconnect

Clear the network buffer when a network connection to or from

 

 

the serial port drops.

 

 

 

 

 

On Active Connection

Clear the network buffer upon initializing a connection.

 

 

 

 

 

On Passive

Clear the buffer upon a connection initiated from the network

 

Connection

to the serial port.

 

 

 

 

 

Flush Output Buffer

 

 

 

 

 

 

 

 

 

At Time of Disconnect

Clear the buffer when the network connection to or from the

 

 

device is dropped.

 

 

 

 

On Active Connection

Clear the buffer with a new connection initiated from the

 

 

device to the network.

 

 

 

 

On Passive

Clear the buffer with a connection from the network to the

 

Connection

device.

 

 

 

 