Configuration Using DeviceInstaller WiPortâ„¢ User Guide 3-7
Connection Response A single character is transmitted to the serial port when there
is a change in connection state. Default setting is None.
Disconnection
Disable Hard Disconnect The TCP connection closes even if the remote site does not
acknowledge a disconnect request.
Disconnect with
modem_control_in The connection drops when modem_control_in transitions
from a high state to a low state.
Disconnect with EOT The connection is dropped when Ctrl-D or Hex 04 is detected.
Both Telnet mode and Disconnect with EOT must be enabled
for Disconnect with EOT to function properly. Ctrl D is only
detected going from the serial port to the network.
Inactivity Timeout Use this parameter to set an inactivity timeout. The unit drops
the connection if there is no activity on the serial line before
the set time expires. Enter time in the format mm:ss, where m
is the number of minutes and s is the number of seconds. To
disable the inactivity timeout, enter 00:00.
Connection
Connection LED Select Blink for the status LEDs to blink upon connection or
None for no LED output.
Buffer Flushing
Flush Input Buffer
At Time of Disconnect Clear the network buffer when a network connection to or from
the serial port drops.
On Active Connection Clear the network buffer upon initializing a connection.
On Passive
Connection Clear the buffer upon a connection initiated from the network
to the serial port.
Flush Output Buffer
At Time of Disconnect Clear the buffer when the network connection to or from the
device is dropped.
On Active Connection Clear the buffer with a new connection initiated from the
device to the network.
On Passive
Connection Clear the buffer with a connection from the network to the
device.