Symptom-to-FRU index

Error messages

Symptom or error

FRU or action, in sequence

 

 

 

Device address conflict.

1.

Load “Setup Defaults” in the BIOS

 

 

Setup Utility.

 

2.

Backup battery.

 

3.

System board.

 

 

 

Allocation error for device.

1.

Load “Setup Defaults” in the BIOS

 

 

Setup Utility.

 

2.

Backup battery.

 

3.

System board.

 

 

 

Failing bits: nnnn.

1.

DIMM.

 

2.

System board.

 

 

 

Invalid system configuration data.

1.

DIMM.

 

2.

System board.

 

 

 

I/O device IRQ conflict.

1.

Load “Setup Defaults” in the BIOS

 

 

Setup Utility.

 

2.

Backup battery.

 

3.

System board.

 

 

 

Hibernation error.

1.

Restore the system configuration to

 

 

what it was before the computer

 

 

entered hibernation mode.

 

2.

If memory size has been changed,

 

 

re-create the hibernation file.

 

 

 

Fan error.

1.

Fan.

 

2.

Thermal grease.

 

3.

System board.

 

 

Thermal sensing error.

System board.

 

 

Cannot boot from any device.

Check the status of device which you want

 

to boot from.

 

Device not found.

 

1.

The device you want to boot from.

 

2.

System board.

 

Device Error.

 

1.

The device you want to boot from.

 

2.

System board.

 

No valid operating system.

 

1.

Check that the operating system has no

 

 

failure and is installed correctly.

 

2.

Reinstall the operation system.

 

Excluded from boot order.

 

v Enter the BIOS Setup Utility and add the

 

 

device in boot order.

 

 

 

48MT 8747, 8749, 9440, 9441, 9442, 9443, and 9448

Page 54
Image 54
IBM MT 9441, MT 9448, MT 8747, MT 9440, MT 9443, MT 9442, MT 8749 manual Error messages