➃DAY/NIGHT External Signal Input & Alarm Signal Output
This is a function to receive the external DAY/NIGHT signal from the
Esensor(option) and convert the signal into BW. The MOTION DET function generates an alarm signal when a movement is detected.
DAY/NIGHT IN
①
GND
➁
ALARM OUT
Connect an external sensor to the DAY/NIGHT terminal as shown in | ① then | |
connect any external device such as a buzzer or lamp to the ALARM |
| |
terminal as shown in | ➁. |
|
The ALARM output terminal is an open collector with the following capacity: DC 16V and 100mA.
OFF : Open contact
ON : Below 100mA
The DAY/NIGHT input terminal has the input of DC 5V
OFF : Open contact
ON : Closed contact
⑤Camera Operation Switch(Setup Switch)
The function of the camera operation switch changes depending on
whether the camera is currently in the usual operation mode(No setup | E |
menu is seen on the screen) or the setup menu mode. |
|
[LEFT/RIGHT] key |
|
[UP/DOWN] key |
|
[ENTER] key
In the usual operation mode
[LEFT/RIGHT] key : Press key for about 2 seconds and the
menu comes out to control the DC IRIS level. The [LEFT] key raises the level and the [RIGHT] key lowers the level.
[ENTER] key : It is used to enter the Setup menu.(Press it about 2 seconds.)
In the setup menu mode
[UP/DOWN] key : These keys move up or down the cursor.
[LEFT/RIGHT] key : These keys move the cursor to the left or right or identify the values sequentially which can be assigned in each setup menu.
[ENTER] key : It is used to enter a
clicking the setup menu or to set the current value.
➅Power Connection Port
This port is connected to the power(adapter) cable.
10 | 11 |