SHR-2040/2041/2042 USER’S MANUAL
●Quality
Quality will be determined.
Select the one among Very High/High/Normal/Low.
●Rate
Sets the Rate the number of screen recorded every second.
It you set to 15ips, the system records too many screens per second and play continues intermittently since recording is more detailed. This is appropriate for concentrated monitoring zone setup.
In case of NTSC, select the one of 30 ips/ 15 ips/ 10 ips/ 7.5 ips/ 5 ips/ 3 ips/ 1 ips.
In case of PAL, select the one of 25 ips/ 12.5 ips/ 8.33 ips/ 6.25 ips/ 5 ips/ 2.5 ips/ 1 ips.
●The Event Recording setup menu will be activated depending on Video On/Off in Camera Setup
●When the video size in the Camera Setup Menu is set to Half D1 and less than 2 cameras are activated, the frame rate of recording may start from 30ips(NTSC)/25ips(PAL) and when the video size in the recording mode is set to Half D1 and more than 3 cameras are activated, the frame rate of recording may start from 15ips(NTSC) / 12.5ips(PAL). CIF supports from 30ips(NTSC) / 25ips(PAL) regardless of the number of activated camera.
●
Event time
Records the situation until Alarm is issued.
Off : No recording
5sec/ 10sec/ 20sec/ 30sec : The recording time options before Alarm issue
●Post-Event
Event time
Records the situation since Alarm is issued.
Off : No recording
5sec/ 10sec/ 20sec/ 30sec/1min/3min/5min/10min/20min: Sets the recording time after an event occurs.