Samsung SCC-C6405P manual Alarm SET, Other SET

Page 27

6. ALARM SET

It consists of 4 ALARM INPUTs and 3 ALARM OUTs.It can sense an ALARM input from exterior SENSORs and it performs with PRESET or PATTERN function and outputs the ALARM OUT signals.

The Alarm will be recognized only when its input lasts more than 150ms and the alarm operation time depends on the Preset Dwell time corresponding to the alarm and whether AUTO is involved.

AUTO SET

This menu designates what to do at the time of ALARM input. Once an alarm is given, the camera will shortly move to the PRESET position corresponding to the respective alarm as follows.

PRESET1 to ALARM1 PRESET2 to ALARM2 PRESET3 to ALARM3 PRESET4 to ALARM4 PRESET5 to MOTION

After DWELL TIME at a PRESET position, PATTERN or SCAN will be in action according to the AUTO SET setup.

E

* * MAIN MENU * *

CAMERA SET...

VIDEO SET...

PRESET...

ZONE SET...

AUTO SET...

ALARM SET...

OTHER SET...

SYSTEM INFO...

Press [Enter]

( ALARM SET)

ALARM PRIORITY SET ...

ALARM IN SET.. ALARM OUT SET.. AUTO SET..

AUX OUT CONTROL..

RET

Setup of OFF/1/2/3/HALF1/HALF2/FULL/SCAN1~4 is available.

OFF dues not perform PATTERN or SCAN after moved to PRESET and each menu has its own function as follows.

1 : PATTERN1,

2 : PATTERN2,

3 : PATTERN3,

HALF1 : Continuous operation of PATTERN1 + PATTERN2

HALF2 : Continuous operation of PATTERN2 + PATTERN3

FULL : Continuous operation of all the aboves

SCAN 1~4 : Scanning as set

ALARM PRIORITY SET

This sets the priority of the 4 ALARM inputs so ALARM can work corresponding to the priority.

The priority of the DEFAULT is ALARM1: 1, ALARM2: 2, ALARM3: 3,

ALARM4: 4, MOTION: 5.

If the ALARM is working at the same time and the priority is the same, it will operate according to the DEFAULT priority. While the ALARM is working, it cannot detect MOTION.

ALARM IN SET

This sets the input TYPE to "NO" (Normal Open), "NC" (Normal Close), or "OFF" depending on the features of the SENSOR connected.

ALARM OUT SET

Each ALARM input corresponds to one of the 3 ALARM OUT.

AUX OUT CONTROL

This sets the ALARM OUT motion to continue or act only when the ALARM is working.

If it is set to OFF the ALARM OUT motion will operate only when the ALARM is working.

(Active "Low"), and if it's set to ON, the ALARM OUT will always operate regardless of the ALARM.

7. OTHER SET

PROPORTIONAL P/T

This function controls the PAN/TILT speed to the ZOOM magnification ratio during the manual operation of PAN/TILT. If you set PROPORTIONAL P/T to ON, the PAN/TILT speed will increase in the ZOOM WIDE mode and decrease in the ZOON TELE mode even in the same manual operation.

3-27

3-28

Image 27
Contents SCC C6405P Safety Precautions Important Safety InstructionsFCC Statement Before Usage Table of contents SCC-C6405 P Overvie w ChapterLocations of Control Camera Address Setup Adapter Connection Initial SettingCC-C6405P Installatio n Before Installing Wall Mount Adaptor SADT-100WM Ceiling Mount Bracket SBR-100DCMPole Mount Adaptor SADT-100PM Indoor Housing SHG-120Outdoor Housing SHG-220 Ceiling Mount Adaptor SADT-100CMInstalling the Camera Setup Menu Overview Camera ID Camera SET MenuSync COLOR/BWExit Motion DETZoom Speed Digital ZoomShutter Video SET MenuIris ALCAGC Gain AGCMotion White BALFocus Mode SpecialDIS Preset Zone SET Zone DIR SET/ZONE Area SET SET Zone AreaSET Zoom ReverseZone Area Zone EnableZone DIR SET LocationAuto SET Play Number Auto PlayScan Auto ReturnOther SET Alarm SETSystem Info Function Key Short KeysSCC-C6405 Product specificationsSCC-C6405P
Related manuals
Manual 30 pages 41.98 Kb Manual 151 pages 26.57 Kb Manual 30 pages 23.63 Kb