Lightolier VPA2G27PP332 dimensions Features, Mounting Methods, Dimensions

Page 1
SECTION 2/Folio G05-30 REV. A

 

VP PARABOLIC VPA2G27PP332

Page 1 of 2

2'x4' RECESSED FLUORESCENT, 4" DEEP, 27 CELL (3x9) PARABOLIC LOUVER

 

STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)

Features

Meets IES RP1 for lighting VDT areas with intense use.

66% efficient (T8).

1.5 spacing mounting ratio.

Only 6" deep body.

One-piece housing.

Specular low iridescence pre-anodized louver.

Spring-loaded latches.

Concealed “T” hinges.

Louver frame with integral positive light stop.

Earthquake clips included.

Louver has protective film dust guard.

Air closure strips (optional).

Air flow pattern dampers (optional).

UL-Listed twin knockout access plate.

Construction to meet Chicago Plenum Code is available.

MOUNTING METHODS

G exposed T-grid ceiling.

 

 

 

 

1/4" max.

 

 

 

 

1-1/2" max.

 

 

24"

15/16"

 

 

 

 

 

or 1"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

concealed Z-spline ceiling.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-

1/8" min.

 

 

 

24-11/16"

3-

3/4" max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

plaster ceiling/flanged.

 

 

 

 

 

 

 

 

 

 

 

 

 

1-

1/8" min.

 

 

 

 

3-

3/4" max.

 

 

24-11/16"

13/16"

 

 

 

 

 

 

 

 

 

 

 

T exposed slot T-grid ceiling.

 

 

 

1-7/8" max.

 

 

24"

9/16"

 

 

 

 

 

 

 

 

direct concealed two directional

 

T

 

T-grid ceiling. (see options for

splay trim).

1/4" max.

1-7/8" max.

24"

drywall kit (see options).

Type “G”

Fixture

Support (by others)

Drywall (by others)

Ceiling 24-5/16"15/16"

Opening

DIMENSIONS

 

 

 

6" (152mm)

 

 

 

 

 

 

 

24" (610mm)

 

 

 

 

6" (152mm)

 

 

 

 

 

2"x2-1/2" access plate

 

 

 

 

Air supply slots

 

 

 

with two K.O.s (7/8" dia.)

 

(VPA only)

 

 

 

 

 

 

3-1/2"

(89mm)

39-1/4" (997mm)

47-31/32" (1218mm)

Job Information

Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

Lightolier a Genlyte Thomas Companywww.lightolier.com Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Image 1
Contents Dimensions FeaturesMounting Methods Specifications Options & AccessoriesSpecifications Photometry