Lightolier PRA1GRFVA232 Photometry, Ordering Information, Options & Accessories, Specifications

Page 2
Section 1A/Folio E20-40

 

PRISMALYTE plus PRA2GRFVA232

Page 2 of 2

2'x4' RECESSED FLUORESCENT, FLOATING LENS FRAME WITH BLACK REVEAL

 

STATIC OR AIR SUPPLY/RETURN, 2 LAMP, T8 OR T12

PHOTOMETRY

MODEL NO. PRA2GRFVA232

 

 

Luminaire Efficacy Rating

 

 

 

LER-61.2 Watts-63.1 BF-0.87

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

85

82

79

77

75

73

74

72

70

ratio

2

78

72

67

68

64

61

66

62

60

3

72

64

58

61

56

52

59

55

51

cavity

4

66

57

51

54

49

45

53

48

44

5

61

51

45

49

43

39

47

43

39

room

6

56

47

40

44

39

35

43

38

34

7

52

42

36

41

35

31

39

34

31

 

8

49

39

32

37

32

28

36

31

28

 

9

46

36

29

34

29

25

33

28

25

 

10

43

33

27

32

26

23

31

26

23

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

room size

 

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

 

66

70

77

84

 

 

65

68

74

81

20

30

 

 

 

60

64

69

75

 

 

60

63

66

72

20

40

 

 

 

56

59

64

69

 

 

58

60

63

66

20

60

 

 

 

53

56

59

64

 

 

56

58

60

62

30

20

 

 

 

68

72

76

82

 

 

67

70

74

80

30

30

 

 

 

61

64

68

73

 

 

62

64

66

71

30

40

 

 

 

57

60

63

67

 

 

59

61

62

65

30

60

 

 

 

53

56

58

62

 

 

57

58

59

61

30

80

 

lengthwise

 

52

54

55

59

 

crosswise

56

58

57

59

40

40

 

 

58

61

63

67

 

60

62

63

65

40

20

 

 

 

70

73

77

82

 

 

69

72

75

80

40

30

 

 

 

63

66

69

73

 

 

64

66

67

71

40

60

 

luminaries

 

54

56

58

61

 

luminaries

58

59

59

61

40

80

 

 

52

54

54

58

 

57

58

57

59

40

100

 

 

 

52

53

53

55

 

 

57

58

56

57

60

30

 

 

 

64

67

70

74

 

 

65

67

69

72

60

40

 

 

 

60

62

64

67

 

 

61

63

64

66

60

60

 

 

 

55

57

58

61

 

 

59

60

59

61

 

 

 

60

80

 

 

 

53

54

54

57

 

 

57

58

57

59

60

100

 

 

 

53

53

52

55

 

 

57

58

56

57

100

40

 

 

 

63

65

66

69

 

 

64

66

66

68

100

60

 

 

 

59

60

60

63

 

 

61

62

61

63

100

80

 

 

 

56

57

56

59

 

 

60

60

59

60

100

100

 

 

 

55

55

54

56

 

 

59

59

57

58

ORDERING INFORMATION

Explanation of Catalog Number. Example: PRA2GRFVA232120SORF

PR

2

 

 

 

RF

 

VA

 

2

BODY STYLE:

A=Air Handling

S=Static

PRISMALYTE plus:

Floating

Lens Frame

Recessed

Fluorescent

Troffer

 

CEILING TYPE:

LENS/SHIELDING

LAMP TYPE/

 

G= Grid

TYPE:

FIXTURE LENGTH:

 

(lay-in T bar)

VA=Virgin acrylic

32=T8

 

T=Slot grid or

(standard), see

34=T12

 

two-directional

options and

(Nominal 48")

FIXTURE

concealed T

LENS FRAME: consult factory

LAMP

WIDTH

see options)

RF=1/2" regressed

QUANTITY

 

floating aluminum frame with 7/16" black reveal four sides.

VOLTAGE:

 

OPTIONS:

120 or 277

Add appropriate

 

suffix to catalog no.,

 

 

ie: (RF)

BALLAST TYPE:

 

1–2 Lamp Mag. T12

LE

<10THD

 

<20THD

1–2 Lamp Elec. T8

SO*

HI*

LOL T8 Dimming

PS

*Instant Start Standard

Other dimming options. Consult factory.

OPTIONS & ACCESSORIES

SPECIAL LENSES: Substitute VB for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight per square foot. Substitute VI for VA (standard) =

.125" nominal pattern 12 with 6.8 oz. average weight per square foot. SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ14 S2 SPLAY TRIM. AIR CLOSURE STRIP: SUFFIX ACS4 (factory installed).

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: RF.

ELECTRICAL WIRING OPTIONS: Consult factory.

DRYWALL KIT: Order Catalog Number: FK92X4.

Request Folio OA30-10.

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .82. To prevent glare the VCP shall be not less than 55 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1649 candelas per square meter. To control veiling reflections, luminaire output in the 30° - 90° zone shall not be less than 68.7%.

AIR HANDLING: (PRA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided

SPECIFICATIONS (continued)

through the lamp compartment through fixture body ends.

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe handling. FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENSES: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pat- tern 12). VB (optional) .125" nominal pattern 12 with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Image 2
Contents Job Name Cat. No Lamps Volts/Ballast DimensionsMounting Methods Photometry Options & AccessoriesSpecifications Ordering Information