Samsung AR18JRFNEWKNMG English-43, Smooth the cut edges, Cut off the remaining foam insulation

Page 43

Installing and connecting the assembly pipe of the indoor unit

Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used.

There are 2 refrigerant pipes of different diameters:

 

07stIn

 

 

• The smaller one is for the liquid refrigerant

 

lla

• The larger one is for the gas refrigerant

 

 

n

A short pipe is already fitted to the air conditioner. You may

 

atio

 

 

need to extend the pipe using the assembly pipe (optional).

 

 

The connection procedure for the refrigerant pipe varies

 

 

according to the exit position of the pipe when facing the wall:

 

 

• Right(A)

A

B

• Left(B)

 

C

• Underside(C)

 

 

 

• Rear

 

 

1.Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit unless you connect the pipe directly from the rear.

2.Smooth the cut edges.

3.Remove the protection caps of the pipes and connect the assembly

pipe to each pipe. Tighten the nuts first with your hands, and then with a torque wrench, applying the following torque:

• If you want to shorten or extend the pipes, refer to page 44~45.

4.Cut off the remaining foam insulation.

5.If necessary, bend the pipe to fit along the bottom of the indoor unit. Then pull it out through the appropriate hole.

The pipe should not project from the rear of the indoor unit.

The bending radius should be 100 mm or more.

Outer Diameter

Torque

 

 

N•m

kgf•cm

 

 

 

 

ø6.35 mm

14~18

140~180

 

 

 

ø9.52 mm

34~42

350~430

 

 

 

ø12.70 mm

49~61

500~620

 

 

 

ø15.88 mm

68~82

690~830

 

 

 

6.Pass the pipe through the hole in the wall.

7.For further details on how to connect to the outdoor unit and evacuate the air, refer to page 48~50.

• The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test;

refer to page 52 for further details.

• Tighten the flare nut with torque wrench according to specified method.

If the flare nut is over-tightened, the flare may break and cause refrigerant gas leakage.

DO NOT WALL UP THE PIPE CONNECTION !

All refrigerant pipe connection must be easy accessible and serviceable.

English-43

MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-05188A-00_UX.indd 43

2/17/2015 2:14:14 PM

Image 43
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningOperation ranges Checking before useEnglish-10 English-11 Technical SpecificationsAR24JRFNCWK/MG English-12English-13 Checking the name of the partsMain parts DisplayRemote controller buttons Checking the remote controllerEnglish-14 Inserting the batteries Remote controller displayLow Battery warning Storing the remote controllerBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-17 English-18 Adjusting the air flow directionVertical air flow Horizontal air flowEnglish-19 Setting the On/Off timerSetting the On timer You can adjust the fan speed in Cool/Fan/Heat ARJQ modeEnglish-20 Setting the Off timerButton Mode Additional options available in modeEnglish-21 English-22 Step cooling functionPress the Options button Using the Fast functionUsing the Comfort function English-23English-24 Using the Single User functionPress the Single user button Setting the Beep sound Using the Auto Clean functionEnglish-25 Cleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit Such as thinner, kerosene and acetone etc. to cleanRemove the air filter from the main body Cleaning the air filterRemoving the Air filter English-27English-28 Reassembling the Air filterTop of the Air filter into the main body.. ➀ English-29 Maintaining the air conditionerTake the cover off and take TroubleshootingAir conditioner English-30Heard when refrigerant flow movement changes. It is normal Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Error is indicatedEnglish-32 General informationIndoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerOutdoor Unit Where sulfide gas existsEnglish-34 English-35 When installing more than 1 outdoor unitTop view Side view English-36 AccessoriesAccessories in the indoor unit case Accessories in the outdoor unit caseTools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsEnglish-38 Assembling the hanger screwEnglish-39 This QR code for detail video of indoor unit installationRemoving the screws Removing the Cover panel Before mounting the indoor unitEnglish-40 Assembling the Cover panel After mounting the indoor unitEnglish-41 Connecting the assembly cableCable specification Connecting the cableEach wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-42 Torque English-43Smooth the cut edges Cut off the remaining foam insulationCutting or extending the pipe Evacuating the indoor unitEnglish-44 English-45 English-46 Drain hose installationEnglish-47 Changing direction of the drain hoseCheck for leakage on both side of the drain outlet Drain hole Drain plug Evacuating the connected pipesEnglish-48 Connect a drain hose to the drain plugIf you use a pipe shorter than 4 m24JFB or Adding RefrigerantEnglish-49 If you use a pipe longer than 4 m24JFB orCylinder with siphon English-5007stIn llan atio To check for gas leaks on the outdoor unit Performing the gas leak testsEnglish-51 Outer Tightening torqueFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-52 English-53 Smart Install modeOff / Blinking / On English-54English-55 Final check and trial operationEnglish-56 Packing and unpacking guideEnglish-57 How to connect your extended power cablesAtio English-58 English-59 021-8255 CE English-60

AR18JQFSBWK/MG, AR12JRFNBWK/MG, AR24JRFNCWKXMG, AR24JRFNCWKNMG, AR24JRFNCWK/MG specifications

Samsung has consistently been a pioneer in the field of air conditioning technology, and their latest models, including the AR18JRFNEWKXMG, AR18JQFNEWKXMG, AR18JRFNEWKNMG, AR18JQSDBWK/MG, and AR24JQFNCWK/MG, exemplify this commitment to innovation and performance. Each of these units is equipped with advanced features designed to enhance comfort and efficiency in any setting.

One of the prominent characteristics of these models is the Digital Inverter technology. By adjusting the compressor's speed based on the cooling demand, this feature significantly reduces energy consumption compared to traditional models, leading to lower electricity bills while maintaining optimal room temperature. This energy efficiency is further bolstered by the units’ high Seasonal Energy Efficiency Ratio (SEER) ratings, ensuring that they operate smoothly even in extreme temperature conditions.

In addition to energy efficiency, these Samsung air conditioners are designed for convenience and ease of use. They come with a Smart Wi-Fi feature, allowing users to control their AC units remotely via a smartphone app. This capability not only provides comfort but also adds to the user-friendly experience by enabling programmable schedules and real-time monitoring of energy consumption.

Another noteworthy feature is the Air Purification System. Equipped with a triple filter system, including a PM 1.0 filter, these units capture and eliminate dust, allergens, and harmful particles from the air, resulting in improved indoor air quality. This is particularly beneficial for individuals with allergies or respiratory conditions.

Noise reduction is another area where these models shine. With near-silent operation, users can enjoy a peaceful environment without the disturbing sounds often associated with traditional air conditioning units. This is complemented by the sleek and modern design, which seamlessly fits into various home décors.

All of these features come together to create air conditioning solutions that not only provide exceptional cooling performance but also contribute to a sustainable lifestyle. Samsung’s dedication to customer-centric design and cutting-edge technology makes these models an excellent choice for anyone seeking reliable and efficient climate control solutions in their homes or offices.