Samsung AR09FSFTKWQNET Connecting the assembly cable, Cable specification, Connecting the cable

Page 32

Fixing the installation plate

2. Fix the indoor unit.

If you fix the indoor unit on a wall

(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.

• If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20mm.

Plastic

Anchor

<20mm

Wall

If you fix the indoor unit on a window frame

(1)Determine the positions of the wooden uprights to be attached to the window frame.

(2)Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

(3)Attach the installation plate to the wooden upright using tapping screws.

If you fix the indoor unit on a gypsum board

(1)Use stud finder to find out locations of the studs.

(2)Fix the plate hanger on two studs.

• Search for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger.

Fix the installation plate without inclining to one side.

Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not

strong enough to withstand the product weight, the unit could fall and cause injury.

Connecting the assembly cable

Cable specification

Model

Power cable

Interconnection cable

Type GL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AR09/12FSFT

3G, 2.5mm² H07RN-F

3G, 1.5mm² H07RN-F

 

20A

2* 0.75mm² H05RN-F

 

 

 

 

 

 

AR18/24FSFT

3G, 2.5mm² H07RN-F

3G, 1.5mm² H07RN-F

 

25A

2* 0.75mm² H05RN-F

 

 

 

 

 

 

Connect the power cable to the auxiliary circuit breaker. If every pole fails to connect to the power supply, it must be incorporated in a wire with a contact opening of ≥3mm.

Connecting the cable

Electrical work

(1)For electrical and earth works, comply with the‘technical standards of electrical installations’and the the wiring regulations’of the Electricity Enterprises Act.

(2)Tighten the terminal block screw to under 12kgf.cm.

(3)Precautions when connecting terminal blocks of the indoor unit

Before connecting, make sure the connecting part of the terminal socket is facing upwards.

 

The terminal

There is no ring

Upside down

socketis damaged.

terminalto cover the wire.

 

There must be no space between the terminal and the screw when connected.

- Any remaining space may become a fire hazard due to overheating of the electrical contact.

 

 

Either the screw is not fitted

 

 

The terminal socket is

properly or there is a space between

upside down.

the screw and the ring terminal.

For the terminal block wiring, use a wire with a ring terminal socket only.

Regular wires without a ring terminal socket may become a fire hazard due to overheating of the electrical contact during a wiring work.

32

Boracay ZE_AR09FSFT@_IBIM_DB68-03378A_EN.indd 32

2012-12-7 15:05:14

Image 32
Contents Boracay ZEAR09FSFT@IBIMDB68-03378AEN.indd 2012-12-7 Contents Safety precautions Important safety symbols and precautionsPersonal injury or death Personal injury or property damageFor Installation Caution For Using Do not touch the circuit breaker with wet hands Do not place objects or devices under the indoor unit Do not touch the pipes connected with the product Do not operate the appliance with wet handsDo not drink the water from the air conditioner For Cleaning Do not clean the inside of the air conditioner by yourselfChecking before use Operation rangesPower button Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Button to adjust the temperature PressAdjusting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowWhen the air conditioner is on and in cool/heat mode Press the button on the remote controllerMode Press the Time Up or Time Down button to set the timeSetting the On/Off timer Press the On Timer/Off Timer buttonCancel Press the Cancel button Additional options available in On timer modeUsing the Smart Saver function From the moment you have set the timerIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsing the Quiet function Using the Auto Clean functionWhen the air conditioner is turned on You can reduce the noise generated from an indoor unitCleaning the air conditioner Make sure the power is turned off and unplugged fromCleaning the indoor unit Cleaning the outdoor unit heat exchangerCleaning the air filter Removing the Air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaClean the condensate drain pan Maintaining the air conditionerTroubleshooting Working Cannot adjust the temperature Fan speed Timer functionIndicator Air flow Check if you have selected Auto/Dry Mode.General information Included Models RemarkChoosing the installation location Installing the unitPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor UnitWhen installing more than 1 outdoor unit When the air outlet is towards the wall Figure Description Top view Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the cable Connecting the assembly cableCable specification Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberSmooth the cut edges Cut off the remaining foam insulationPurging the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flarePipe 50 Pa. The joint must be accessible and serviceable Correct InclinedCracked Outer DiameterDrain hose installation Changing direction of the drain hoseEnsure that condensation draining is adequate Purging the connected pipesConnect a drain hose to the drain plug Adding Refrigerant If you use a pipe longer than 5mIf you use a pipe shorter than 5m Model1975 Please fill in with indelible ink the factory refrigerant charge of the product Performing the gas leak tests To check for gas leaks on the outdoor unitTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesOutdoor unit installed on the wall by rack Then place the indoor unit on the installation plateFixing the indoor unit in place Fixing the outdoor unit in placeFinal Check and Trial Operation How to connect your extended power cables Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with Insulation tape to finishEnglish Questions or COMMENTS? Air Conditioner
Related manuals
Manual 45 pages 3.43 Kb Manual 45 pages 23.12 Kb Manual 1 pages 28.11 Kb Manual 47 pages 49.79 Kb Manual 45 pages 45.25 Kb Manual 1 pages 30.65 Kb Manual 45 pages 732 b Manual 43 pages 53.57 Kb Manual 45 pages 260 b

AR12FSFTKWQNZE, AR09FSFTKWQNET, AR12FSFTKWQNET, AR09FSFTKWQNZE specifications

The Samsung AR09FSFTKWQNZE and AR12FSFTKWQNET represent a new standard in air conditioning technology, designed to deliver maximum comfort and efficiency. These models incorporate state-of-the-art features that cater to the needs of modern households.

One of the standout characteristics of the AR series is its advanced inverter technology. This feature allows the air conditioner to adjust its cooling output in real-time, providing consistent temperatures while consuming less energy. This results in lower electricity bills and reduced environmental impact, making it an eco-friendly choice for consumers.

Another remarkable aspect is the Turbo Cooling function, which ensures rapid cooling of spaces, achieving the desired temperature in a significantly shorter time. This is especially beneficial during hot summer days when immediate relief from heat is essential. Additionally, the models come equipped with a Good Sleep Mode, which optimizes the cooling process to ensure a comfortable sleeping environment by maintaining a steady temperature throughout the night.

The air purifying capabilities of the Samsung AR09FSFTKWQNZE and AR12FSFTKWQNET cannot be overlooked. Each unit features a multi-layered filtration system that effectively captures dust, allergens, and odors in the air, promoting a healthier indoor atmosphere. This technology is particularly advantageous for individuals with allergies or respiratory issues.

These air conditioners also prioritize user convenience through features such as Wi-Fi connectivity and Smart Control. Users can manage their cooling preferences remotely via a smartphone app, allowing for greater flexibility and ease of use. This integration with smart home systems enhances the overall user experience.

In terms of design, the Samsung AR series sports a sleek and modern aesthetic that can seamlessly blend into any interior decor. The easy-to-clean surfaces and discreet appearance further add to their appeal.

Overall, the Samsung AR09FSFTKWQNZE, AR12FSFTKWQNET, AR09FSFTKWQNET, and AR12FSFTKWQNZE air conditioners exemplify cutting-edge cooling technology. With their focus on energy efficiency, air purification, and user-friendly features, they represent an ideal choice for consumers seeking comfort, convenience, and environmental responsibility in their HVAC solutions. Whether for a small apartment or a large house, these models are designed to meet diverse cooling needs while enhancing the quality of indoor air.