Samsung AR12FSFTKWQNET manual Changing direction of the drain hose, Drain hose installation

Page 37

Drain hose installation

1.If necessary, connect the 2-meter extension drain hose to the drain hose.

2.If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.

3.Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain hose tightly with a clamp.

• If you do not use the other drain hose hole,

block it with a rubber stopper.

4. When extending the Drain Hose, hold the end of Drain Hose and Extended

 

Hose, rotate and insert the drain hose into Extended hose for 15~20 mm. Make

Drain hose hole

sure the two hoses are firmly connected, there is no water leakage.

 

5.Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose. Then, Use vinyl tape to wrap the each side of connection by 20mm .

ENGLISH

 

 

15~20 mm

Drain hose

Extension

Drain hose

Extension

 

drain hose

 

 

 

drain hose

6.Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.

7.Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture.

8.Using natural drainage method, check the drainage is normal.

20mm 20mm or more or more

Vinyl Tape Foam Insulation

Shield

Drain hose

Extension drain hose

• The hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page

41~42 for further details.

• Make sure the installed direction of the drain hose is correct. Inadequate installation may cause condensate water leakage.

• If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.

DO NOT WALL UP THE DRAIN HOSE CONNECTION !

Drain hose connection must be easy accessible and serviceable.

Changing direction of the drain hose

Change the direction only when it is necessary.

Screw hole

1.

Detach the rubber cap with the plier.

Screw

2.

Detach the drain hose by pulling it and turning to the left.

 

3.

Insert the drain hose by fixing it with the screw into the groove of the drain

Drain hose

 

hose and the outlet of the drain pan.

 

4.

Attach the rubber cap with a screwdriver by turning it to the right until it

 

fixes to the end of the groove.

Drain pan outlet

 

 

5.

Check for leakage on both side of the drain outlet.

 

Pour the water in direction of arrow.

Rubber cap

 

Direction of the drained water

Make sure the indoor unit is in upright position when you pour water to check for leakage.

Make sure that the water does not overflow onto the electrical part.

37

Boracay ZE_AR09FSFT@_IBIM_DB68-03378A_EN.indd 37

2012-12-7 15:05:16

Image 37
Contents Boracay ZEAR09FSFT@IBIMDB68-03378AEN.indd 2012-12-7 Contents Important safety symbols and precautions Safety precautionsPersonal injury or death Personal injury or property damageFor Installation Caution For Using Do not touch the circuit breaker with wet hands Do not place objects or devices under the indoor unit Do not drink the water from the air conditioner Do not operate the appliance with wet handsDo not touch the pipes connected with the product Do not clean the inside of the air conditioner by yourself For CleaningOperation ranges Checking before useChecking the name of the parts Power buttonMain parts DisplayRemote controller buttons Checking the remote controllerBattery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press Button to adjust the temperatureUsing the Turbo function Adjusting the air flow directionPress the Air swing button on the remote controller Vertical air flowPress the button on the remote controller When the air conditioner is on and in cool/heat modeMode Press the Time Up or Time Down button to set the timePress the On Timer/Off Timer button Setting the On/Off timerCancel Press the Cancel button Additional options available in On timer modeFrom the moment you have set the timer Using the Smart Saver functionIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsing the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on You can reduce the noise generated from an indoor unitMake sure the power is turned off and unplugged from Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerRemoving the Air filter Cleaning the air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaMaintaining the air conditioner Clean the condensate drain panTroubleshooting Timer function Working Cannot adjust the temperature Fan speedIndicator Air flow Check if you have selected Auto/Dry Mode.Included Models Remark General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyOutdoor Unit Where sulfide gas existsWhen the air outlet is towards the wall When installing more than 1 outdoor unit Figure Description Top view Side viewAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryCut off the remaining foam insulation Smooth the cut edgesCutting or extending the pipe Purging the indoor unitUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flareCorrect Inclined Pipe 50 Pa. The joint must be accessible and serviceableCracked Outer DiameterChanging direction of the drain hose Drain hose installationConnect a drain hose to the drain plug Purging the connected pipesEnsure that condensation draining is adequate If you use a pipe longer than 5m Adding RefrigerantIf you use a pipe shorter than 5m Model the factory refrigerant charge of the product Please fill in with indelible ink1975 To check for gas leaks on the outdoor unit Performing the gas leak testsTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesThen place the indoor unit on the installation plate Outdoor unit installed on the wall by rackFixing the indoor unit in place Fixing the outdoor unit in placeFinal Check and Trial Operation Apply heat to the contraction tube to contract it How to connect your extended power cablesAfter tube contraction work is completed, wrap it with Insulation tape to finishEnglish Questions or COMMENTS? Air Conditioner
Related manuals
Manual 45 pages 3.43 Kb Manual 45 pages 23.12 Kb Manual 1 pages 28.11 Kb Manual 47 pages 49.79 Kb Manual 45 pages 45.25 Kb Manual 1 pages 30.65 Kb Manual 45 pages 732 b Manual 43 pages 53.57 Kb Manual 45 pages 260 b

AR12FSFTKWQNZE, AR09FSFTKWQNET, AR12FSFTKWQNET, AR09FSFTKWQNZE specifications

The Samsung AR09FSFTKWQNZE and AR12FSFTKWQNET represent a new standard in air conditioning technology, designed to deliver maximum comfort and efficiency. These models incorporate state-of-the-art features that cater to the needs of modern households.

One of the standout characteristics of the AR series is its advanced inverter technology. This feature allows the air conditioner to adjust its cooling output in real-time, providing consistent temperatures while consuming less energy. This results in lower electricity bills and reduced environmental impact, making it an eco-friendly choice for consumers.

Another remarkable aspect is the Turbo Cooling function, which ensures rapid cooling of spaces, achieving the desired temperature in a significantly shorter time. This is especially beneficial during hot summer days when immediate relief from heat is essential. Additionally, the models come equipped with a Good Sleep Mode, which optimizes the cooling process to ensure a comfortable sleeping environment by maintaining a steady temperature throughout the night.

The air purifying capabilities of the Samsung AR09FSFTKWQNZE and AR12FSFTKWQNET cannot be overlooked. Each unit features a multi-layered filtration system that effectively captures dust, allergens, and odors in the air, promoting a healthier indoor atmosphere. This technology is particularly advantageous for individuals with allergies or respiratory issues.

These air conditioners also prioritize user convenience through features such as Wi-Fi connectivity and Smart Control. Users can manage their cooling preferences remotely via a smartphone app, allowing for greater flexibility and ease of use. This integration with smart home systems enhances the overall user experience.

In terms of design, the Samsung AR series sports a sleek and modern aesthetic that can seamlessly blend into any interior decor. The easy-to-clean surfaces and discreet appearance further add to their appeal.

Overall, the Samsung AR09FSFTKWQNZE, AR12FSFTKWQNET, AR09FSFTKWQNET, and AR12FSFTKWQNZE air conditioners exemplify cutting-edge cooling technology. With their focus on energy efficiency, air purification, and user-friendly features, they represent an ideal choice for consumers seeking comfort, convenience, and environmental responsibility in their HVAC solutions. Whether for a small apartment or a large house, these models are designed to meet diverse cooling needs while enhancing the quality of indoor air.