Desa SH-5597 manual Installation, CAUTION To Avoid Fire Or Burn Hazards, White to White, Black to

Page 2
INSTALLATION

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

 CAUTION: To Avoid Fire Or Burn Hazards: CAUTION: To Avoid Fire Or Burn Hazards:

• Allow fixture to cool before touching. The bulb and

 

the fixture operate at high temperatures.

Keep fixture at least 2" (51 mm) from combustible

 

materials. Do not aim at objects closer than 3' (1 m).

Use only T4 100W (max.), G8 tungsten halogen

The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Route all fixture wires through the large holes in the gasket as shown.

Connect the junction box wires to the light fixture wires as shown.Twist together and secure with wire connectors.

bi-pin 120 VAC lamps.

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Swing the sensor head towards the clamp

screw joint.

Controls

Clamp Screw

Rotate the sensor head clockwise 180° so the

Mounting

Strap

White to

White

Black to

Black Rubber Plug

Mounting

Bolt

Gasket

controls face down.

Controls

White to Controls Black tocontrols face down.

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

BULB INSTALLATION

NOTE: When re-lamping, turn power off and let the fixture cool.

To remove lamp shade, loosen set screw 2 full turns with a small flat-head screwdriver.Turn shade counterclockwise and remove.

To remove bulb, pull straight out of fixture.

To replace bulb, push bulb pins into lamp socket. Check that the bulb is seated properly.

To reinstall lamp shade, place shade on fixture and align notches on shade with tabs on fixture. Turn clockwise. Tighten set screw firmly.

WIRE THE LIGHT CONTROL

BULB INSTALLATION WARNING: Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Install mounting strap to junction box using screws appropriate for your junction box.

Connectanyfixturegroundwire(s)andthecoverplate ground screw to the junction box ground wire.

MOUNT THE LIGHT CONTROL

Place the Mounting Bolt through the front of the junction box cover. Push the small gasket hole over the Mounting Screw.

Make sure the wire connectors and wires are inside the junction box. Align the Mounting Screw with the center hole in the Mounting Strap.Secure the fixture to the Mounting Strap.

Push the Rubber Plug firmly into place.

Ifawetlocationjunctionboxwasnotused,caulkthewall plate mounting surface with silicone weather sealant.

Lamp Shade

WIRE THE LIGHT CONTROL Set Screw

Lock Nuts

Keep lamps at least 2" (51 mm) from the

sensor and 2" (51 mm) from combustibles.

Adjust the lamp holders by loosening the lock nuts, but do not rotate the lamp holders more than 180° from the factory setting.

Adjust lamp shades by loosening the set screws several turns, turn shades counterclockwise and remove.Reinstall the shades in the desired position and tighten set screws.

2

598-1162-01

Image 2
Contents Move ON-TIMESwitch to FeaturesDUALBRITE TIMER Flip light switch offWIRE THE LIGHT CONTROL INSTALLATIONBULB INSTALLATION CAUTION To Avoid Fire Or Burn HazardsTurn on the circuit breaker and light switch TEST AND ADJUSTMENTSPECIFICATIONS Bottom of SensorNo Service Parts Available for this Product TROUBLESHOOTING GUIDETECHNICAL SERVICE TEN YEAR LIMITED WARRANTYModelo SH-5597 Detector de Movimiento y Control de LuzFUNCIONAMIENTO Característicasdio o quemazón INSTALACIONCUIDADO Para evitar los peligros de incen lámina deParte de abajo del detector PRUEBA Y AJUSTEESPECIFICACIONES Angulo deNo enviar los productos GUIA DE INVESTIGACION DE AVERIASSERVICIO TÉCNICO GARANTÍA LIMITADA A 10 AÑOS