TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.
❒Turn the RANGE control to the mid position, DUALBRITE® to OFF and the
MAX |
| DUAL BRITE™ | ||
| O | |||
| B |
|
| |
| O |
|
| |
| S |
|
| |
| T |
|
| |
MIN | TEST 1 5 20 | OFF 3 6 DUSK TO | ||
RANGE | ||||
| MINUTES | HOUR DAWN |
Bottom of Sensor
Avoid aiming the control at:•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
240°
❒ Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.
❒ Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times whenmotionisdetected).Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 2" (2.5 cm) away from the lamps.
❒Adjust the RANGE as needed. RANGE set too high may
increase false triggering.
❒ Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.
❒Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes).
❒Set the DUALBRITE® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs.,
NOTE: DUALZONE™ is a new zone of detection which was added as an option to select Heath®/Zenith motion sensing products. This feature adds a zone of detec- tion under the motion sensor. DUALZONE™ requires no additional adjustment and operates in conjuction with the
15 ft. |
|
|
(4.6 m) | DUALZONE™ | |
| ||
DUALZONE™ | 70 ft. 100 ft. |
|
(21 m) (30.5 m) |
| |
| Boosted | Maximum |
|
| |
Maximum Range | Coverage Angle |
The detector is less sensitive to motion directly towards it.
MotionMotion
DUALZONE™ | Sensor | DUALZONE™ |
|
| |
Least Sensitive |
| Most Sensitive |
SPECIFICATIONS
Horizontal Range. . . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [varies with surrounding temperature]
Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80°
Vertical
Electrical Load. . . . . . Up to 200 Watt Maximum In- candescent [Up to 100 Watt Maximum each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO, and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 20 minutes
DUALBRITE® Timer . . . . 3, 6 hours,
VAC
DESA Specialty Products™ reserves the right to dis- continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
3 |