Page 14

probably rise by a few degrees (if you do not use the exhaust hose.) The Dehumidifying mode will not work in temperatures below 64°F.

Cooling

1)Plug the power cord into a power outlet.

2)Turn on the unit.

3)Press the Mode button until the icon LED next to “Cool” lights up.

4)Select the fan speed by using the Fan button.

5)Set the thermostat using the Temperature / Time buttons. The thermostat is

adjustable between 64°F and 90°F in one degree increments.

Cooling mode cools and dehumidifies your air. If the ambient temperature drops below the temperature you selected, the compressor turns off and the unit functions with the fan only. When the temperature rises above the temperature you selected, the compressor turns on again.

Note:

The exhaust hose must be used in Cooling mode in order to cool a room.

Fan-only

1)Plug the power cord into a power outlet.

2)Turn on the unit.

3)Press the Mode button until the LED next to “Fan” lights up.

4)Select the fan speed by using the Fan button.

Fan-only mode is used to circulate the air in your room. No temperature setting is needed.

Note:

Fan-only mode does not require that the exhaust hose be attached.

4) Water Drainage

All air conditioners dehumidify the air as they cool. This portable air conditioner is designed to evaporate and exhaust this condensed water (sometimes called condensate). When using the Cooling or Dehumidifying modes under extremely humid conditions, the internal water tray may fill completely. If this happens, the Water Level indicator on the control panel will light and the compressor will shut off (so that no water is spilled on the floor.) The unit will continue operating and exhausting water until the water level lowers. Then the compressor will turn back on and the unit will begin cooling as normal.

If you want to begin cooling or dehumidifying right away without waiting for the unit to dispose of the excess condensate itself, you may manually drain the unit.

Manual Drainage

Turn the unit off. Unscrew the cap from the upper drain port. Connect a drain hose to the upper drain port (one is included with this unit, or you may use a garden hose.) Put the other end of the drain hose in a bucket. Turn the unit back on. The internal drain

13

Image 14
Contents Page Table of Contents Thank You Energy Saving TipsTechnical Specifications AP310SSSafety Precautions Page Parts and Accessories PartsInstallation AccessoriesExhaust Hose Installation Mounting the exhaust hoseWindow Installation Control Panel Wall InstallationOperation How to set the Off Timer Remote Control ModesWater Drainage CoolingMaintenance Cleaning the Exterior FilterLong Term Storage Down Dr ai n Por tTroubleshooting Problem Possible Cause SolutionPage Circuit Diagram PCBLimited Warranty What is Covered